HP Surestore Disk Array FC60 HP SureStore E Disk Array 12H User's and Service - Page 179
Failed Local, Address Decode
View all HP Surestore Disk Array FC60 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 179 highlights
Troubleshooting Troubleshooting Event Code Descriptions Event Number (DEC/hex) Event Name 210/0xd2 Correctable ECC Error During Initialization Event Predictive Suspected Logged Maintenance Components Implication Description Y More than 1 SIMM in 6 months if Controller no operator activity The controller experienced an unrecoverable error during power on. This is expected in any of the following situations: - The batteries have been fully discharged. - The batteries were disconnected from the memory - New SIMM memory was added All other situations, this event represents a true memory error. 211/0xd3 Controller Y Ignore if SIMM Failed Local corrected by Controller Address Decode reset or power Test cycle. A controller was discovered to be bad during power on. Specifically, the secondary controller appears to have failed the request to perform a local memory decode test or was unable to establish communication with the other controller. This may be recovered by power cycle or reset. 212/0xd4 Controller Y Ignore if SIMM Failed Remote corrected by Controller Address Decode reset or power Backplane Test cycle. A controller was discovered to be bad during power on. Specifically, the secondary controller appears to have failed the request to perform a remote memory decode test or was unable to establish communication with the other controller. This may be recovered by power cycle or reset. 179