HP Surestore Disk Array FC60 HP SureStore E Disk Array 12H User's and Service - Page 149
Initialization Failed. The drive, An Add Physical Drive
View all HP Surestore Disk Array FC60 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 149 highlights
Troubleshooting Troubleshooting Event Code Descriptions Event Number (DEC/hex) Event Name Event Predictive Suspected Logged Maintenance Components Implication Description 65/0x41 Optimal Space Y Ignore Error In RAID 1 None The controller detected that space allocated for an "optimal only" migrating write (i.e. rebuild policy) was no longer optimal after the write had completed. This event is logged for debugging purposes only and requires no action. 66/0x42 No Shutdown Image Posted N NA None The controller could not shutdown the disk array because all the disk drives were missing. Reinstall the missing disks to shutdown the array. 67/0x43 Bad Disk Drive State During Add Physical Drive N NA None An Add Physical Drive command failed with the disk returning a status of Initialization Failed. The drive is failing initialization, so information on the nature of the failure should appear in the event log in a separate entry. 68/0x44 Internal SCSI Underrun N NA None A disk drive sent/received less data than expected. 69/0x45 Internal SCSI Overrun N NA None A disk drive sent/received more data than expected. 70/0x46 Internal SCSI Timeout N More than 2 Disk Drive A disk drive didn't respond occurrences Controller within a specified time limit. per hot plug event Internal SCSI The disk drive may be failing, bus or it may be busy performing data retries. 149