Troubleshooting Troubleshooting Event Code Descriptions Event Number (DEC/hex) Event Name Event Predictive Suspected Logged Maintenance Components Implication Description 32/0x20 Disk Drive Data Transfer Failed N NA None The I/O completed with status indicating the data transfer failed. All retries are exhausted or the I/O is not retryable. 33/0x21 Disk Drive Miscompare on Write And Verify Y Single Disk Drive The read verify following a Occurrence Controller write indicated a Miscompare Internal SCSI error status. All retries are Bus exhausted or the I/O is not retryable. 34/0x22 Disk Drive State Y Ignore Conflict None A disk drive was in the wrong state for read, write or pass through. For a read or write, the wrong states are "down", "missing", or "initialization failed". For pass through, the wrong state is "missing". Check the state of the disk drive and try to return it to "ready" by adding it if it was downed, or reinstalled it if it is missing. 35/0x23 Disk Drive Data Out Of Sync After Access Y Ignore - See None accompanying errors Data being read or written to a disk drive was out of sync after the access was complete. The redundant copy of the data stored on the disk drive is no longer valid. A rebuild will ensure the data is valid. 142