HP Surestore Disk Array FC60 HP SureStore E Disk Array 12H User's and Service - Page 160
Table Overflow, Host Activity
View all HP Surestore Disk Array FC60 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 160 highlights
Troubleshooting Troubleshooting Event Code Descriptions Event Number (DEC/hex) Event Name Event Predictive Suspected Logged Maintenance Components Implication Description 141/0x8d Cancel Rebuild Complete Y Ignore - None Operator or Host Activity The cancellation of a rebuild has completed. 142/0x8e Disk Drive Table Overflow Y Ignore - Operator activity None The controller is capable of retaining information about 16 drives. Disk drives that are removed from the array and enter the missing drive list are included in this count. If the total number of disk installed in the array plus any missing drives ever exceeds 16, this condition is logged. The disk array always generates a data unavailable warning before this condition is reached. Once the 16 disk limit is reached, the controller will not recognize any additional drives installed in the array. Because the controller cannot add the new disks to the drive list, the status light on the newly installed disk will remain amber. To correct his problem and maintain data integrity, find and reinstall the missing disks. If the data on the disk array is not critical, the disk array can be reformatted with the new disks. . 160