Specs Appendix A. Product Specifications Operating Characteristics and Requirements Packaging Dimensions Packaging Height Disk Array 706 mm (27.8 in.) Width 610 mm (24.0 in.) Depth 508 mm (20.0 in.) Operating Characteristics and Requirements Power Requirements: NOTE! Power requirements are specified for a unit during spin-up with a maximum configuration of three fan modules, three power modules, twelve disk modules, and two controller modules. • 870 W (7.3 A at 120 Vac, 3.8 A at 230 Vac) Airflow Space • Minimum: 102 mm (4 in.) front and rear Heat Dissipation • Minimum Configuration: 135 watts (460 Btu/hr; 115 kcals/hr) • Maximum Configuration: 750 watts (2560 Btu/hr; 645 kcals/hr) • Typical Configuration (with twelve 9.1-Gigabyte 7200 rpm disk modules in the enclosure): 420 watts (1433 Btu/hr; 361 kcals/hr) 212