HP Surestore Disk Array FC60 HP SureStore E Disk Array 12H User's and Service - Page 23
Suppressing Single-Controller Warning Messages, System State: System Warning
View all HP Surestore Disk Array FC60 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 23 highlights
Description Product Description Controller Module Suppressing Single-Controller Warning Messages When a single controller disk array is powered on for the first time, the control panel may display a "System Warning" error message, which occurs because only one controller is installed. By default, the disk array assumes that there should be two controllers installed, and therefore it will generate singlecontroller error messages until you suppress them. If a "System Warning" error message is displayed on the front panel, you must first verify that it is caused by the detection of a single controller. Use the control panel keys to verify the source of the message by using the following key sequence: KEY CANCEL CANCEL MENU - ENTER + DISPLAY "System Warning" "Language" "View Settings" "System State: System Warning" "Warning: Single Controller" To avoid future single-controller warning messages, you can suppress them using the arraymgr ARM command line utility. The arraymgr utility is described in further detail in the System Administrator's Guide, which is shipped with each disk array. 23