HP Surestore Disk Array FC60 HP SureStore E Disk Array 12H User's and Service - Page 176
Note: The NVRAM is not, Fan Missing
View all HP Surestore Disk Array FC60 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 176 highlights
Troubleshooting Troubleshooting Event Code Descriptions Event Number (DEC/hex) Event Name Event Predictive Suspected Logged Maintenance Components Implication Description 198/0xc6 Fan Failed Y Single Fan Occurrence Controller Backplane A fan has failed and should be replaced. 199/0xc7 Power Supply Failed Y Single Power Supply A power supply has failed and Occurrence Controller should be replaced. Backplane 200/0xc8 Power Down Due To Fan Failure Y Single Fans Occurrence Controller Backplane The controller has detected that not enough fans are functioning to cool the disk array properly. As a result, the controller is shutting off the power supply to avoid overheating. Note: The NVRAM is not posted to disk, so it is critical to repair the system quickly. 201/0xc9 Fan Missing At Initialization Y Ignore - See None accompanying errors. 202/0xca Power Down Due To Missing Fan Y Single Occurrence Fan Controller Backplane During startup, the controller detected that a fan had been removed from the enclosure. The total length of time a fan has been missing will be checked periodically and when it exceeds approximately 10 minutes, the controller will shut off the power supply. The controller is shutting off the power supply because a fan has been missing from the enclosure for too long (approximately 10 minutes). 176