HP Surestore Disk Array FC60 HP SureStore E Disk Array 12H User's and Service - Page 181
Memory Error, ECC Errors
View all HP Surestore Disk Array FC60 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 181 highlights
Troubleshooting Troubleshooting Event Code Descriptions Event Number (DEC/hex) Event Name Event Predictive Suspected Logged Maintenance Components Implication Description 215/0xd7 Secondary Controller Failed With Memory Error Y Ignore if SIMM SIMM Controller configurations Backplane do not match A controller was discovered to be bad during power on. Specifically, the secondary controller appears to have failed due to some memory error or violation. If the memory contents on each board does not match (in number), this error can occur. Additionally, if a memory component fails, it will cause this error. This will occur if a different number of SIMMs are used on each controller. 216/0xd8 Secondary Controller Failed, Communication ECC Errors Y See None accompanying errors A controller was discovered to be bad during power on. Specifically, the secondary controller appears to have failed due to the inability for the communication area of NVRAM to be cleared of ECC errors. 217/0xd9 Secondary Controller Failed To Enable RAM Mirroring Y See None accompanying errors A controller was discovered to be bad during power on. Specifically, the secondary controller appears to have failed due to the mirror not coming to an up state within 1 second of power on. 181