Panasonic WJSX650 WJSX650 User Guide - Page 44
Reference No., Notes, Explanation, PATROL1S to PATROL4S, _: Scene [PATROLS] setting - digital camera
View all Panasonic WJSX650 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 44 highlights
Reference No. 46 47 48 49 Explanation 1 to 1024: Alarm Output number Alarm output signal is supplied from the ALARM OUT 1/2 port or the SERIAL port. (65 to 1024 are supplied from the SERIAL port only as a serial command.) Note: To activate serial command transmission, set Alarm Output to ON in "Communication" - "Serial Command". Spot: Only the spot images can be activated for the alarm event. Tour Sequence: Only tour sequences can be activated for the alarm event. Group Sequence: Only group sequences can be activated for the alarm event. Note: You cannot change the Display Mode if an alarm event has been associated with the monitor. To change the setting, you need to delete the alarm event setting or change the monitor setting for the alarm event. Available digits: 5 or less Available numerics: 0 to 9 Notes: • Begin the entry with a numeric other than "0". • 99999 is not available. Available digits: 5 or less Available numerics: 0 to 9 Note: Begin the entry with a numeric other than "0". 50 1 to 5: Level 51 View & Operate: An operator can display the selected camera image on the selected monitor. The oper- ator can also control the camera. View: An operator can display the selected camera image on the selected monitor, but cannot control the camera. --: The operator can neither display the selected camera image on the selected monitor nor control the camera. 52 User ID: Select a registered User ID. 53 1, 3, 5, 10, 30, or 60 min: If no operations are performed during this period in the login status, the operator logs out of the system automatically. 54 1 to 2: Video output board No. 55 Available parameters: 1 to 4096 56 OFF: Alarm occurrence is not notified. 0 sec: Every time alarm occurrence is detected, system controllers are notified. 1 sec, 3 sec, 5 sec: 1 second, 3 second, or 5 seconds after the alarm occurrence, system controllers are notified. 57 OFF: Alarm notification is not retried. 100 ms, 200 ms, 400 ms, 1 sec: Period until alarm notification is retried 58 0 to 16: Total recorder number Note: When camera input channels to supply video input signals from recorders are set to "RS485" in "System" - "RS485 Camera", the RS-485 settings are automatically canceled. 60 ON, OFF, AUTO, _: B/W setting 61 PATROL1(S) to PATROL4(S) , _: Scene [PATROL(S)] setting 62 ON: Perform OFF: Not perform Note: Depending on the specifications of recorders, recording may be stopped for several seconds at the timing of auto time adjustment. 63 ON: Perform OFF: Not to perform Note: To perform auto time adjustment, check the specifications of connected device before the setting. 64 OFF: Not notify 1, 5, 10, 30 or 60 sec Select the interval to notify the system status. (Recommended: 5 or more sec) 44