Panasonic WJSX650 WJSX650 User Guide - Page 52

System, Data Port, Serial Port, Vd2/data/cable Compensation, Rs485 Camera, Comm.

Page 52 highlights

I SYSTEM You will perform the system settings required to transmit data between the unit and connected devices. When you select SYSTEM on the top menu, the following menu is displayed. 500 SYSTEM 510 DATA PORTO 520 SERIAL PORT BCOMMUNICATION STATUS (8/ NONE/1) 38400 530 VD2/DATA/CABLE COMPENSATIONO 540 RS485 CAMERAO G SYSTEM Menu • DATA PORT DATA PORT menu will be displayed. You will select the DATA port types according to the connected devices. • SERIAL PORT Select the communication speed of SERIAL port. (The factory default is 38 400 bps.) 4 800 bps/9 600 bps/19 200 bps/38 400 bps Other parameters (COMMUNICATION STATUS) are as follows. (Setting change is not available.) Data bit: 8 (bits) Parity check: NONE Stop bit: 1 (bit) • VD2/DATA/CABLE COMPENSATION VD2/DATA/CABLE COMPENSATION menu is displayed. You will perform the settings for VD2, camera control signal (DATA), and cable compensation. • RS485 CAMERA RS485 CAMERA menu is displayed. You will set the RS-485 port numbers and unit numbers for the RS-485 cameras. G DATA PORT Menu 510 DATA PORT OUTPUT BOARD1 OUTPUT BOARD2 DATA 1 2 3 4 5 6 7 8 TYPE TMNL1 PSD HDR1 HDR2 TMNL5 TMNL6 HDR3 HDR4 COMM. 9600 9600 9600 9600 9600 9600 19200 19200 COMMUNICATION STATUS DATA=DATA(TMNL/PCD/HDR) 8/ NONE/1 • TYPE Select the DATA port types according to the connected devices. TMNL1 to 8: Select this when using the DATA port for sys- tem controller in the terminal mode. PSD: Select this when using the DATA port for system con- troller in the PS·Data mode. HDR1 to 4: Select this when connecting a recorder to the DATA port. The available port settings are as follows. DATA1: TMNL1 /PSD (The factory default is TMNL1.) DATA2: TMNL2 (The factory default is TMNL2.) DATA3: TMNL3/HDR1 (The factory default is HDR1.) DATA4: TMNL4/HDR2 (The factory default is HDR2.) DATA5: TMNL5 (The factory default is TMNL5.) DATA6: TMNL6 (The factory default is TMNL6.) DATA7: TMNL7/ HDR3 (The factory default is HDR3.) DATA8: TMNL8/ HDR4 (The factory default is HDR4.) • COMM. Select the communication speed. (The factory default is 9 600 bps.) 4 800 bps/9 600 bps/19 200 bps Parameters of COMMUNICATION STATUS are as follows. (Setting change is not available.) Data bit: 8 (bits) Parity check: NONE Stop bit: 1 (bit) Note: When changing the communication speed, conform the communication speed settings to that of the connected devices. 52

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98

52
SYSTEM
You will perform the system settings required to transmit
data between the unit and connected devices. When you
select SYSTEM on the top menu, the following menu is dis-
played.
SYSTEM Menu
DATA PORT
DATA PORT menu will be displayed. You will select the
DATA port types according to the connected devices.
SERIAL PORT
Select the communication speed of SERIAL port. (The fac-
tory default is 38 400 bps.)
4 800 bps/9 600 bps/19 200 bps/38 400 bps
Other parameters (COMMUNICATION STATUS) are as fol-
lows. (Setting change is not available.)
Data bit:
8 (bits)
Parity check:
NONE
Stop bit:
1 (bit)
VD2/DATA/CABLE COMPENSATION
VD2/DATA/CABLE COMPENSATION menu is displayed.
You will perform the settings for VD2, camera control signal
(DATA), and cable compensation.
RS485 CAMERA
RS485 CAMERA menu is displayed. You will set the RS-485
port numbers and unit numbers for the RS-485 cameras.
DATA PORT Menu
TYPE
Select the DATA port types according to the connected
devices.
TMNL1 to 8:
Select this when using the DATA port for sys-
tem controller in the terminal mode.
PSD:
Select this when using the DATA port for system con-
troller in the PS
·
Data mode.
HDR1 to 4:
Select this when connecting a recorder to the
DATA port.
The available port settings are as follows.
DATA1:
TMNL1 /PSD (The factory default is TMNL1.)
DATA2:
TMNL2 (The factory default is TMNL2.)
DATA3:
TMNL3/HDR1 (The factory default is HDR1.)
DATA4:
TMNL4/HDR2 (The factory default is HDR2.)
DATA5:
TMNL5 (The factory default is TMNL5.)
DATA6:
TMNL6 (The factory default is TMNL6.)
DATA7:
TMNL7/ HDR3 (The factory default is HDR3.)
DATA8:
TMNL8/ HDR4 (The factory default is HDR4.)
COMM.
Select the communication speed. (The factory default is 9
600 bps.)
4 800 bps/9 600 bps/19 200 bps
Parameters of COMMUNICATION STATUS are as follows.
(Setting change is not available.)
Data bit:
8 (bits)
Parity check:
NONE
Stop bit:
1 (bit)
Note:
When changing the communication speed, conform
the communication speed settings to that of the con-
nected devices.
500 SYSTEM
510 DATA PORT
O
520 SERIAL PORT
COMMUNICATION STATUS
38400
(8/ NONE/1)
530 VD2/DATA/CABLE COMPENSATION
O
540 RS485 CAMERA
O
B
510 DATA PORT
DATA
TYPE
COMM.
OUTPUT BOARD1
1
TMNL1
9600
2
PSD
9600
3
HDR1
9600
4
HDR2
9600
OUTPUT BOARD2
5
TMNL5
9600
6
TMNL6
9600
7
HDR3
19200
8
HDR4
19200
COMMUNICATION STATUS
8/ NONE/1
DATA=DATA(TMNL/PCD/HDR)