Clean the Bindexer Sensors Q1205, Q1206, Q1207
UPC - 095205425307
View all Xerox 6180N manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 74 highlights
Solutions in Alphabetical Order between the two parts of the sensor to clear any obstructions. 7. Push the Binder drawer into the machine until it latches. 8. Close the Finisher Doors. Clean the Bindexer Sensors (Q1205, Q1206, Q1207) 1. Open the left Finisher Door using the handle above Paper Tray 3. 2. Open the Bindexer Door. The Bindexer Door, located above the Paper Tray 3 area, has a black handle in the center of a large green sticker. Locate the green triangle pointing to a latch that is surrounded by a light green rectangle. The door opens by grasping the handle as it is moved to the left, and then pulling the handle out. 3. Inside the machine are three shelves, each with an orange roller. Rest your index finger on any one of the rollers. Lift your finger straight up until your fingernail is against the top of the shelf. Slide your finger as far to the left of that shelf as you can. Your index finger should now be resting in a Cshaped opening. There is a C-shaped opening for each shelf and that is where the sensors are located. The Q1207 Sensor is on the top shelf. DT6180 HandyBook 74