Xerox 6180N DocuTech 61xx - Operator HandyBook - Page 84
Clean the Pre-Fuser Sensor Q1009
UPC - 095205425307
View all Xerox 6180N manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 84 highlights
Solutions in Alphabetical Order Clean the Pre-Fuser Sensor (Q1009) CAUTION: The surrounding area of the machine around the sensor can be extremely hot! To clean the Q1009 Sensor: 1. Open the right and left Processor Doors. 2. To the left of Paper Tray 1, at the back of the Fuser Module, locate the area 7 label on the machine frame. 3. Below the label is a cutout area. Look inside the cutout area. You may need to kneel down so you can see inside the cutout. To your left is a clear plastic bottle containing Fuser Agent. Inside the cutout, and coming out on the side of the plastic bottle, is a shiny metal tab. The right surface near the top of that tab is a mirror. About 10 mm (3/8 of an inch) to the right, facing the mirror, is the Q1009 sensor. Also try following the purple and red wires, if you are having difficulties finding the sensor. 4. Pull out the Fuser Module. CAUTION: The Fuser may be hot! 5. Clean the mirror and sensor with a small amount of Lens and Mirror Cleaner on a soft, lint-free cloth. DT6180 HandyBook 84