Xerox 6180N DocuTech 61xx - Operator HandyBook - Page 88

To locate the Q1221 Sensor

Page 88 highlights

Solutions in Alphabetical Order To locate the Q1221 Sensor: 8. Using the Q1218 sensor as a reference point, look about 38 mm (1 1/2 inch) closer to the front of the machine. You should see the round sensor for Q1221 pointing straight up. 9. Put your finger on the sensor and move your head to the left of the big black bracket so you can see your finger on the sensor again. 10. Clean the sensor. 11. Look 76 mm (3 inches) directly above the sensor for orange and white wires. These wires are attached to the detector which faces straight down. 12. Using a soft, lint-free cloth, brush the cloth across the detector. 13. If present, lower the bypass transport. Close the Finisher Top Cover. 14. Close the Finisher Doors. DT6180 HandyBook 88

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168

Solutions in Alphabetical Order
DT6180 HandyBook
88
To locate the Q1221 Sensor:
8.
Using the Q1218 sensor as a reference point, look about 38 mm (1 1/2 inch) closer to the front of
the machine. You should see the round sensor for Q1221 pointing straight up.
9.
Put your finger on the sensor and move your head to the left of the big black bracket so you can
see your finger on the sensor again.
10. Clean the sensor.
11. Look 76 mm (3 inches) directly above the sensor for orange and white wires. These wires are
attached to the detector which faces straight down.
12. Using a soft, lint-free cloth, brush the cloth across the detector.
13. If present, lower the bypass transport. Close the Finisher Top Cover.
14. Close the Finisher Doors.