Yamaha DME32 DME32 Owners Manual - Page 218
GPI interface. Scenes 1 through 4 are assigned to GPI outputs 1 through 4. When
View all Yamaha DME32 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 218 highlights
GPI Connectors 213 The following example shows just how easily the DME32 can be remotely controlled using the GPI interface and a simple switch box. Scenes 1 through 4 are assigned to GPI inputs 1 through 4. When a button is pressed on the remote switch box, the corresponding scene is recalled. A more advanced setup could be used to remotely control component parameters. DME32 Euro-block connector GPI IN 4: Scene 4 GPI IN 3: Scene 3 GPI IN 2: Scene 2 GPI IN 1: Scene 1 8 7 6 5 4 3 2 1 IN +V Euro-block plug Remote switch box 4321 Scene recall buttons The next example shows how the DME32 can remotely control other equipment via the GPI interface. Scenes 1 through 4 are assigned to GPI outputs 1 through 4. When a scene is recalled, the corresponding GPI output is switched from high or low. A more advanced setup could be used to switch a GPI output when a component parameter is turned on or off, or a parameter is adjusted above or below a specified threshold. DME32 Euro-block connector GPI OUT 4: Scene 4 GPI OUT 3: Scene 3 GPI OUT 2: Scene 2 GPI OUT 1: Scene 1 8 7 6 5 4 3 2 1 OUT GND Euro-block plug Triggerable device DME32-Owner's Manual