3Com 8760 User Guide - Page 222
auth-timeout-value, shutdown
UPC - 662705506531
View all 3Com 8760 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 222 highlights
CHAPTER 5: COMMAND LINE INTERFACE Default Setting 30 Command Mode Interface Configuration (Wireless-VAP) Example Enterprise AP(if-wireless g: VAP[0])#association-timeout-interval 20 Enterprise AP(if-wireless g: VAP[0])# auth-timeout-value This command configures the time interval within which clients must complete authentication to the VAP interface. Syntax auth-timeout-value minutes - The number of minutes before re-authentication. (Range: 5-60) Default Setting 60 Command Mode Interface Configuration (Wireless-VAP) Example Enterprise AP(if-wireless g: VAP[0])#auth-timeout-value 40 Enterprise AP(if-wireless g: VAP[0])# shutdown This command disables the wireless interface. Use the no form to restart the interface. Syntax [no] shutdown Default Setting Interface enabled Command Mode Interface Configuration (Wireless-VAP) 5-120