HP StorageWorks P2000 HP StorageWorks P2000 G3 MSA System SMU Reference Guide - Page 118
FA MIB 2.2 objects, descriptions, and values continued, connUnitRevsTable
View all HP StorageWorks P2000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 118 highlights
Table 11 FA MIB 2.2 objects, descriptions, and values (continued) Object Description Value connUnitContact connUnitLocation connUnitEventFilter connUnitNumEvents connUnitMaxEvents connUnitEventCurrID connUnitRevsTable connUnitRevsUnitId connUnitRevsIndex connUnitRevsRevId connUnitRevsDescription connUnitSensorTable connUnitSensorUnitId connUnitSensorIndex connUnitSensorName connUnitSensorStatus connUnitSensorInfo connUnitSensorMessage connUnitSensorType connUnitSensor Characteristic Settable: Contact information for this Default: Uninitialized Contact connectivity unit Settable: Location information for this Default: Uninitialized Location connectivity unit Defines the event severity that will be Default: info(8) logged by this connectivity unit. Settable only through SMU. Number of events currently in the connUnitEventTable Varies as the size of the Event Table varies Maximum number of events that can 400 be defined in the connUnitEventTable Not supported 0 Includes the following objects as specified by the FA MIB2.2 Spec connUnitId of the connectivity unit Same as connUnitId that contains this revision table Unique value for each connUnitRevsEntry between 1 and connUnitNumRevs See External details for connUnitRevsTable on page 121 Vendor-specific string identifying a revision of a component of the connUnit String specifying the code version. Reports "Not Installed or Offline" if module information is not available. Description of a component to which See External details for the revision corresponds connUnitRevsTable on page 121 Includes the following objects as specified by the FA MIB2.2 Spec connUnitId of the connectivity unit Same as connUnitId that contains this sensor table Unique value for each connUnitSensorEntry between 1 and connUnitNumSensors See External details for connUnitSensorTable on page 122 Textual identification of the sensor intended primarily for operator use See External details for connUnitSensorTable on page 122 Status indicated by the sensor ok(3), warning(4), or failed(5) as appropriate for FRUs that are present, or other(2) if FRU is not present. Not supported Empty string Description the sensor status as a message connUnitSensorName followed by the appropriate sensor reading. Temperatures display in both Celsius and Fahrenheit; for example, CPU Temperature (Controller Module A): 48C 118F). Reports "Not installed" or "Offline" if data is not available. Type of component being monitored See External details for by this sensor connUnitSensorTable on page 122 Characteristics being monitored by See External details for this sensor connUnitSensorTable on page 122 118 SNMP reference