HP StorageWorks P2000 HP StorageWorks P2000 G3 MSA System SMU Reference Guide - Page 118

FA MIB 2.2 objects, descriptions, and values continued, connUnitRevsTable

Page 118 highlights

Table 11 FA MIB 2.2 objects, descriptions, and values (continued) Object Description Value connUnitContact connUnitLocation connUnitEventFilter connUnitNumEvents connUnitMaxEvents connUnitEventCurrID connUnitRevsTable connUnitRevsUnitId connUnitRevsIndex connUnitRevsRevId connUnitRevsDescription connUnitSensorTable connUnitSensorUnitId connUnitSensorIndex connUnitSensorName connUnitSensorStatus connUnitSensorInfo connUnitSensorMessage connUnitSensorType connUnitSensor Characteristic Settable: Contact information for this Default: Uninitialized Contact connectivity unit Settable: Location information for this Default: Uninitialized Location connectivity unit Defines the event severity that will be Default: info(8) logged by this connectivity unit. Settable only through SMU. Number of events currently in the connUnitEventTable Varies as the size of the Event Table varies Maximum number of events that can 400 be defined in the connUnitEventTable Not supported 0 Includes the following objects as specified by the FA MIB2.2 Spec connUnitId of the connectivity unit Same as connUnitId that contains this revision table Unique value for each connUnitRevsEntry between 1 and connUnitNumRevs See External details for connUnitRevsTable on page 121 Vendor-specific string identifying a revision of a component of the connUnit String specifying the code version. Reports "Not Installed or Offline" if module information is not available. Description of a component to which See External details for the revision corresponds connUnitRevsTable on page 121 Includes the following objects as specified by the FA MIB2.2 Spec connUnitId of the connectivity unit Same as connUnitId that contains this sensor table Unique value for each connUnitSensorEntry between 1 and connUnitNumSensors See External details for connUnitSensorTable on page 122 Textual identification of the sensor intended primarily for operator use See External details for connUnitSensorTable on page 122 Status indicated by the sensor ok(3), warning(4), or failed(5) as appropriate for FRUs that are present, or other(2) if FRU is not present. Not supported Empty string Description the sensor status as a message connUnitSensorName followed by the appropriate sensor reading. Temperatures display in both Celsius and Fahrenheit; for example, CPU Temperature (Controller Module A): 48C 118F). Reports "Not installed" or "Offline" if data is not available. Type of component being monitored See External details for by this sensor connUnitSensorTable on page 122 Characteristics being monitored by See External details for this sensor connUnitSensorTable on page 122 118 SNMP reference

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142

118
SNMP reference
connUnitContact
Settable: Contact information for this
connectivity unit
Default: Uninitialized Contact
connUnitLocation
Settable: Location information for this
connectivity unit
Default: Uninitialized Location
connUnitEventFilter
Defines the event severity that will be
logged by this connectivity unit.
Settable only through SMU.
Default: info(8)
connUnitNumEvents
Number of events currently in the
connUnitEventTable
Varies as the size of the Event Table
varies
connUnitMaxEvents
Maximum number of events that can
be defined in the
connUnitEventTable
400
connUnitEventCurrID
Not supported
0
connUnitRevsTable
Includes the following objects as specified by the FA MIB2.2 Spec
connUnitRevsUnitId
connUnitId
of the connectivity unit
that contains this revision table
Same as
connUnitId
connUnitRevsIndex
Unique value for each
connUnitRevsEntry
between 1
and
connUnitNumRevs
See
External details for
connUnitRevsTable on page 121
connUnitRevsRevId
Vendor-specific string identifying a
revision of a component of the
connUnit
String specifying the code version.
Reports “Not Installed or Offline” if
module information is not available.
connUnitRevsDescription
Description of a component to which
the revision corresponds
See
External details for
connUnitRevsTable on page 121
connUnitSensorTable
Includes the following objects as specified by the FA MIB2.2 Spec
connUnitSensorUnitId
connUnitId
of the connectivity unit
that contains this sensor table
Same as
connUnitId
connUnitSensorIndex
Unique value for each
connUnitSensorEntry
between
1 and
connUnitNumSensors
See
External details for
connUnitSensorTable on page 122
connUnitSensorName
Textual identification of the sensor
intended primarily for operator use
See
External details for
connUnitSensorTable on page 122
connUnitSensorStatus
Status indicated by the sensor
ok(3), warning(4), or failed(5) as
appropriate for FRUs that are
present, or other(2) if FRU is not
present.
connUnitSensorInfo
Not supported
Empty string
connUnitSensorMessage
Description the sensor status as a
message
connUnitSensorName
followed
by the appropriate sensor reading.
Temperatures display in both Celsius
and Fahrenheit; for example, CPU
Temperature (Controller Module A):
48C 118F). Reports “Not installed”
or “Offline” if data is not available.
connUnitSensorType
Type of component being monitored
by this sensor
See
External details for
connUnitSensorTable on page 122
connUnitSensor
Characteristic
Characteristics being monitored by
this sensor
See
External details for
connUnitSensorTable on page 122
Table 11
FA MIB 2.2 objects, descriptions, and values (continued)
Object
Description
Value