HP Z600 HP Z600 Workstation Maintenance and Service Guide - Page 198
Diagnostics and troubleshooting, POST error messages, continued - cannot access all ram memory
UPC - 884962074053
View all HP Z600 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 198 highlights
Table 6-10 POST error messages (continued) Screen message Probable cause 164-Memory Size Error Memory configuration is incorrect. 201-Memory Error RAM failure. 202-Memory Type Mismatch Memory modules do not match. Recommended action 1. Run the Computer Setup (F10) Utility or the Windows utilities. 2. Verify that the memory modules are installed properly. 3. If third-party memory has been added, test the memory configuration using HP memory. 4. Verify the memory module type. 1. Run the Computer Setup (F10) utility or Windows operating system utilities. 2. Be sure that memory and continuity modules are installed correctly. 3. Verify the memory module type. 4. Remove and replace memory modules one at a time to isolate faulty modules. 5. Replace faulty memory modules. 6. If the error persists after replacing memory modules, replace the system board. Replace the memory modules with matched sets. 203-Memory module failed self-test and failing rank was disabled Defective memory module. Replace the memory module. 204-Memory module failed Improper module load. and user rank was disabled Reseat the memory module correctly. 205-Memory high temperature detected Insufficient memory module cooling. Verify that a memory module cooling fan is installed and operating. 206-Memory setup invalid Memory configured incorrectly. Reconfigure the memory modules in the proper slots. 207-Incompatible DIMMs detected DIMMs are installed that do not fulfill system requirements. 1. Verify that the memory module type matches workstation requirements. 2. Insert the DIMM in the proper memory socket. 3. Replace the DIMM if the problem persists. 208-Mismatched DIMMs detected Installed DIMMs are improperly matched. Verify that matching DIMMs are installed. 209-Memory warning condition detected Incorrect memory module type in use. Verify that the memory modules are compatible with workstation requirements. 212-Failed Processor 0 Processor has failed to initialize. 1. Reseat the processor in its socket. 2. If the processor does not respond, replace it. 213-Incompatible Memory Modules A memory module in the memory 1. Verify the memory module type. socket identified in the error message is missing critical SPD information, or 2. Insert the DIMM in another memory socket. is incompatible with the chipset. 3. Replace the module with a DIM conforming to the SPD standard. 214-DIMM Configuration Warning DIMMs are not installed correctly (not See the service label on the workstation access panel paired correctly). for the correct memory configurations, and reseat the DIMMs accordingly. 186 Chapter 6 Diagnostics and troubleshooting ENWW