HP xw3400 HP xw3400 Workstation - Service and Technical Reference Guide - Page 158

Solving memory problems

Page 158 highlights

Solving memory problems If you encounter memory problems, some common causes and solutions are listed in the following table. CAUTION: Power may still be supplied to the DIMMs when the workstation is turned off. To avoid damage to the DIMMs or the system board, you must unplug the workstation power cord before attempting to reseat, install, or remove a DIMM module. For those systems that support ECC memory, HP does not support mixing ECC and non-ECC memory. Otherwise, the workstation will not boot the operating system. Table D-13 Solving Memory Problems System will not boot or does not function properly after installing additional memory modules. Cause Solution Memory module is not the correct type or speed grade for the system or the new memory module is not seated properly. Replace module with the correct industry-standard device for the workstation. On some models, ECC and non-ECC memory modules cannot be mixed. Out of memory error. Cause Memory configuration may not be set up correctly. You have run out of memory to run the application. Solution Use the Device Manager to check memory configuration. Check the application documentation to determine the memory requirements. Memory count during POST is wrong. Cause The memory modules may not be installed correctly. Integrated graphics may use system memory. Solution Check that the memory modules have been installed correctly and that proper modules are used. No action required. Insufficient memory error during operation. Cause Too many Terminate and Stay Resident programs (TSRs) are installed. You have run out of memory for the application. Solution Delete any TSRs that you do not need. Check the memory requirements for the application or add more memory to the workstation. 148 Appendix D Troubleshooting without diagnostics ENWW

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182

Solving memory problems
If you encounter memory problems, some common causes and solutions are listed in the following table.
CAUTION:
Power may still be supplied to the DIMMs when the workstation is turned off. To avoid
damage to the DIMMs or the system board, you must unplug the workstation power cord before attempting
to reseat, install, or remove a DIMM module.
For those systems that support ECC memory, HP does not support mixing ECC and non-ECC memory.
Otherwise, the workstation will not boot the operating system.
Table
D
-
13
Solving Memory Problems
System will not boot or does not function properly after installing additional memory modules.
Cause
Solution
Memory module is not the correct type or speed grade for the
system or the new memory module is not seated properly.
Replace module with the correct industry-standard device for the
workstation. On some models, ECC and non-ECC memory
modules cannot be mixed.
Out of memory error.
Cause
Solution
Memory configuration may not be set up correctly.
Use the Device Manager to check memory configuration.
You have run out of memory to run the application.
Check the application documentation to determine the memory
requirements.
Memory count during POST is wrong.
Cause
Solution
The memory modules may not be installed correctly.
Check that the memory modules have been installed correctly
and that proper modules are used.
Integrated graphics may use system memory.
No action required.
Insufficient memory error during operation.
Cause
Solution
Too many Terminate and Stay Resident programs (TSRs) are
installed.
Delete any TSRs that you do not need.
You have run out of memory for the application.
Check the memory requirements for the application or add more
memory to the workstation.
148 Appendix