Icom IC-9100 Instruction Manual - Page 102

Dv Mode Operation

Page 102 highlights

8 DV MODE OPERATION ■ Digital mode operation The IC-9100 can be operated in the digital voice mode, including low-speed data operation, for both transmit and receive. It can also be connected to a GPS receiver* to transmit/receive position data. *Compatible with an RS-232 output/NMEA format/ 4800bps/9600 bps ■ Call sign setting Set the desired "UR," "R1," "R2" and "MY" call signs to be used for DV operation, as described below. NOTE: In the DR mode, you can set only "MY" call sign in the "CS" screen (Call Sign). q Push [DV•DR] to select the DV mode. w P ush [MENU] one or more times to display the "M3" screen (Menu 3). • In the DR mode, push [MENU] once or twice to select the "D1" screen. e P ush [CS](F-1) to display the "CS" screen (Call Sign). • Y ou can push [F-4] to toggle between the call sign and the name. r P ush [Z](F-1) one or more times to display the "UR," "R1," "R2" or "MY" screen. t R otate [MAIN DIAL] to select the desired call sign. • UR : "CQCQCQ," individual station call signs (U01-U99) or destination repeater call signs*1 is selected. • R1 : Y our access/area repeater's call sign is selected. • R2 : "NOT USE✱"*2 or a link/gateway repeater call sign is selected. • MY : Y our own call signs is selected (MY1-MY6). • First selecting the call sign group by pushing [TS•GRP] or [GRP](F-5)*3 makes it more convenient when "UR," "R1" or "R2" is displayed. See the right column for details of the repeater call sign group selection. y P ush [SET](F-4) to set the selected call sign to be used for DV operation. u R epeat steps r to y to set the other call signs. i P ush [Z](F-1) one or more times to return to the "CS" screen. NOTE: You can toggle between displaying the repeater name or the repeater call sign by pushing [NAME](F-4) in the R1 and R2 screens. *1 '/' is displayed in front of the repeater call sign. The repeater call sign with '/' is used for the gateway CQ calling. *2 For an area (local) repeater communication only (Link repeater is not used.) *3 [GRP](F-5) is not used in the DR mode. 93 About the Time-Out Timer function The IC-9100 has a Time-Out Timer function for digital repeater operation. The timer limits a continuous transmission to approximately 10 minutes. Warning beeps will sound approximately 30 seconds before time-out and then again immediately before time-out. Be sure to turn ON the function before operating in the digital mode. (p. 162) [CS]/[√] [SET] [MENU] [DVɾDR] [MAIN DIAL] M3 CS C D R > C S U R DSET CS UR CQCQCQ Ú MY J A 3 Y U A R1 R2 NOT USE UR ≈CQCQCQ UR Ú CLR EDT NAME GRP Rotate [MAIN DIAL] UR ≈JG3YMK Ú ɹU01 SET GRP UR ≈JG3YMK ɹUR Ú CLR EDT NAME GRP How to select the repeater call sign group: Hold down [TS•GRP] or [GRP](F-5)*3 for 1 second to enter the group selection mode. Then rotate [MAIN DIAL] to select the desired group. After selecting, push [TS•GRP] or [GRP](F-5)*3 to display the repeater call signs in the group. Or, you can select the repeater group using the keypad key. - Only repeaters assigned to groups are selectable.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212

8
93
DV MODE OPERATION
Digital mode operation
The IC-9100 can be operated in the digital voice mode,
including low-speed data operation, for both transmit
and receive. It can also be connected to a GPS re-
ceiver* to transmit/receive position data.
*Compatible with an RS-232 output/NMEA format/
4800bps/9600 bps
Call sign setting
Set the desired
“UR,” “R1,” “R2” and “MY”
call signs to
be used for DV operation, as described below.
NOTE:
In the DR mode, you can set only “MY” call
sign in the “CS” screen (Call Sign).
q
Push [DV
DR] to select the DV mode.
w
P
ush [MENU] one or more times to display the “M3”
screen (Menu 3).
• In the DR mode, p
ush [MENU] once or twice to select
the “D1” screen.
e
P
ush [CS](F-1) to display the “CS” screen (Call
Sign).
•You can push [F-4] to toggle between the call sign and
the name.
r
P
ush [
Z
](F-1) one or more times to display the
“UR,” “R1,” “R2” or “MY” screen.
t
Rotate [MAIN DIAL] to select the desired call sign.
UR : “CQCQCQ,” individual station call signs
(U01–U99) or destination repeater call
signs*
1
is selected.
• R1 :Your access/area repeater’s call sign is se
-
lected.
R2 : “NOT USE
”*
2
or a link/gateway repeater call
sign is selected.
• MY :Your own call signs is selected (MY1–MY6).
• First selecting the call sign group by pushing [TS•GRP]
or [GRP](F-5)*
3
makes it more convenient when “UR,”
“R1” or “R2” is displayed. See the right column for de-
tails of the repeater call sign group selection.
y
Push [SET](F-4) to set the selected call sign to be
used for DV operation.
u
Repeat steps
r
to
y
to set the other call signs.
i
Push [
Z
](F-1) one or more times to return to the
“CS” screen.
NOTE:
You can toggle between displaying the re
-
peater name or the repeater call sign by pushing
[NAME](F-4) in the R1 and R2 screens.
*
1
‘/’ is displayed in front of the repeater call sign. The
repeater call sign with ‘/’ is used for the gateway CQ
calling.
*
2
For an area (local) repeater communication only
(Link repeater is not used.)
*
3
[GRP](F-5) is not used in the DR mode.
[CS]/[
]
[SET]
[MENU]
[DV
DR]
[MAIN DIAL]
CS
CD
R>CS
UR
DSET
M3
CS
U
R
CQCQCQ
JA3YUA
M
Y
R
1
R
2
NOT USE
Ú
UR
Ú
UR
CLR
CQCQCQ
EDT
NAME GRP
UR
Ú
UR
CLR
JG3YMK
EDT
NAME GRP
UR
Ú
U01
JG3YMK
SET
GRP
Rotate [MAIN DIAL]
How to select the repeater call sign group:
Hold down [TS
GRP] or [GRP](F-5)*
3
for 1 second to
enter the group selection mode. Then rotate [MAIN
DIAL] to select the desired group. After selecting,
push [TS•GRP] or [GRP](F-5)
*
3
to display the re-
peater call signs in the group.
Or, you can select the repeater group using the key-
pad key.
- Only repeaters assigned to groups are selectable.
About the Time-Out Timer function
The IC-9100 has a Time-Out Timer function for digi-
tal repeater operation. The timer limits a continuous
transmission to approximately 10 minutes. Warning
beeps will sound approximately 30 seconds before
time-out and then again immediately before time-out.
Be sure to turn ON the function before operating in
the digital mode. (p. 162)