Icom IC-9100 Instruction Manual - Page 156

Scan set mode

Page 156 highlights

11 SCANS ■ Scan set mode The scan speed, Scan Resume function and [MAIN DIAL] scan function can be set in the Scan Set mode. q P ush [MENU] one or more times to display the "M2" screen (Menu 2). w P ush [SCAN](F-1) to display the "SCAN" screen. e P ush [SET](F-5) to enter the Scan Set mode. r P ush [Y](F-1) or [Z](F-2) to select the desired item. t R otate [MAIN DIAL] to select the desired option. • Hold down [F-3] for 1 second to reset to the default value. y P ush [MENU] to save, and return to the "SCAN" screen. u P ush [MENU] again to return to the "M2" screen (Menu 2). 1. SCAN Speed (Default: HIGH) Select the desired scan speed between high and low. • HIGH : The scan is faster. • LOW : The scan is slower. 2. SCAN Resume (Default: ON) Set the Scan Resume function ON or OFF. • ON : When a signal is detected, the scan pauses for 10 seconds, then resumes. When a signal disappears, the scan resumes 2 seconds later. • OFF : W hen a signal is detected, the scan is cancelled. 3. MAIN DIAL (SCAN) (Default: Up/Down) Select how the [MAIN DIAL] functions, during a scan. • OFF : Rotating [MAIN DIAL] cancels the scan. • Up/Down : R otating [MAIN DIAL] changes the scan- ning direction. [SCAN [SET] [MENU] [F-3] [MAIN DIAL] M2 SCAN M E M S W R TCON V S C Push SCAN PROG:P1 ∂F: ±10k PRO ∂F F I N SPAN S E T S E T SCAN Speed Ù 1Ú Push HIGH Push S E T SCAN Resume Ù 2Ú ON Push S E T MAIN DIAL (SCAN) Ù 3Ú Up/Down 147

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212

147
11
SCANS
Scan set mode
The scan speed, Scan Resume function and [MAIN
DIAL] scan function can be set in the Scan Set mode.
q
P
ush [MENU] one or more times to display the “M2”
screen (Menu 2).
w
Push [SCAN](F-1) to display the “SCAN” screen.
e
Push [SET](F-5) to enter the Scan Set mode.
r
Push [
Y
](F-1) or [
Z
](F-2) to select the desired
item.
t
Rotate [MAIN DIAL] to select the desired option.
• Hold down [F-3] for 1 second to reset to the default
value.
y
Push [MENU] to save, and return to the “SCAN”
screen.
u
Push [MENU] again to return to the “M2” screen
(Menu 2).
[SET]
[SCAN]/[
]
[MENU]
[F-3]
[MAIN DIAL]
[
]
SCAN
MEM
SWR
TCON
VSC
M2
PRO
F
SPAN
SET
FIN
SCAN
PROG:P1
F
:
±
10k
Ú
SCAN Speed
Ù
1
HIGH
SET
Ú
SCAN Resume
Ù
2
ON
SET
Ú
MAIN DIAL (SCAN)
Ù
3
Up/Down
SET
SCAN Speed
1.
(Default: HIGH)
Select the desired scan speed between high and low.
• HIGH
: The scan is faster.
• LOW
: The scan is slower.
SCAN Resume
2.
(Default: ON)
Set the Scan Resume function ON or OFF.
• ON
: When a signal is detected, the scan pauses for
10 seconds, then resumes. When a signal dis-
appears, the scan resumes 2 seconds later.
• OFF: When a signal is detected, the scan is can
-
celled.
MAIN DIAL (SCAN)
3.
(Default: Up/Down)
Select how the [MAIN DIAL] functions, during a scan.
• OFF
: Rotating [MAIN DIAL] cancels the scan.
• Up/Down : Rotating [MAIN DIAL] changes the scan
-
ning direction.
Push
Push
Push
Push