Icom IC-9100 Instruction Manual - Page 158

Programmed scan/Fine programmed scan VFO mode

Page 158 highlights

11 SCANS ■ Programmed scan/Fine programmed scan (VFO mode) A programmed scan searches for signals between Program Scan Edge channels "1A-3A" and "1b-3b." Before starting the programmed scan, scan edges must be programmed into these channels. See the previous page for scan edge programming. If the same frequencies are programmed into the Program Scan Edge channels, the programmed scan will not start. q P ush [VFO/MEMO] to select the VFO mode. w P ush the mode switch to select the desired operat- ing mode. • T he operating mode can also be changed while scan- ning. e P ush [TS] one or more times to select a tuning step. (p. 38) • The tuning step can also be changed while scanning. r P ush [MENU] one or more times to display the "M2" screen (Menu 2). t P ush [SCAN](F-1) to display the "SCAN" screen. y Set [RF/SQL] open or closed. • The scan performance differs, depending on the squelch setting when the scan was started. See page 146 for details. • If the [RF/SQL] control function is set to "AUTO," the squelch is always open in the SSB, CW and RTTY modes. (pp. 44, 162) u H old down [PRO](F-1) for 1 second to select the desired scan range between "P1," "P2" and "P3." • The scan searches between programmed scan channels 1A-1b (P1), 2A-2b (P2) or 3A-3b (P3). i Push [PRO](F-1) to start the programmed scan. • T he MHz and kHz decimal points, and the selected scan range display blink while scanning. • If "Up/Down" is selected as the "MAIN DIAL (SCAN)" option in the Scan Set mode, rotating [MAIN DIAL] changes the scanning direction. (p. 147) o W hen the scan detects a signal, the scan stops, pauses or ignores it, depending on the Scan Resume function, the VSC function or the squelch status. !0 Push [PRO](F-1) to cancel the scan. [SCAN]/[PRO] [VFO/MEMO] [TS] [RF/SQL] [MENU] Mode switches M2 SCAN M E M S W R TCON V S C Push SCAN PROG:P1 ∂F: ±10k PRO ∂F F I N SPAN S E T Hold down SCAN PROG:P2 ∂F: ±10k PRO ∂F F I N SPAN S E T Push SCAN PROG SCAN:P2 PRO ∂F F I N SPAN S E T While Programmed scanning D About the Fine programmed scan When a signal is received during Fine programmed scan, the scanning tuning step is temporarily set to 10 Hz and the scan speed decreases. q Start the programmed scan. • Follow steps q through i as described above. w W hile scanning, push [FIN](F-3) to switch the scan function between a programmed scan and a Fine programmed scan. e Push [PRO](F-1) to cancel the scan. 149 SCAN PROG SCAN:P2 PRO ∂F F I N SPAN S E T Push SCAN F−PROG SCAN:P2 PRO ∂F F I N SPAN S E T While Fine programmed scanning

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212

149
11
SCANS
A programmed scan searches for signals between
Program Scan Edge channels “1A–3A” and “1b–3b.”
Before starting the programmed scan, scan edges
must be programmed into these channels.
See the previous page for scan edge programming.
If the same frequencies are programmed into the
Program Scan Edge channels, the programmed
scan will not start.
q
Push [VFO/MEMO] to select the VFO mode.
w
Push the mode switch to select the desired operat-
ing mode.
• The operating mode can also be changed while scan
-
ning.
e
Push [TS] one or more times to select a tuning step.
(p. 38)
• The tuning step can also be changed while scanning.
r
P
ush [MENU] one or more times to display the “M2”
screen (Menu 2).
t
P
ush [SCAN](F-1) to display the “SCAN” screen.
y
Set [RF/SQL] open or closed.
• The scan performance differs, depending on the squelch
setting when the scan was started. See page 146 for
details.
• If the [RF/SQL] control function is set to “AUTO,” the
squelch is always open in the SSB, CW and RTTY
modes. (pp. 44, 162)
u
Hold down [PRO](F-1) for 1 second to select the
desired scan range between “P1,” “P2” and “P3.”
• The scan searches between programmed scan chan
-
nels 1A–1b (P1), 2A–2b (P2) or 3A–3b (P3).
i
Push [PRO](F-1) to start the programmed scan.
• The MHz and kHz decimal points, and the selected scan
range display blink while scanning.
• If
“Up/Down” is selected as
the “MAIN DIAL (SCAN)”
option
in the Scan Set mode, rotating [MAIN DIAL]
changes the scanning direction. (p. 147)
o
When the scan detects a signal, the scan stops,
pauses or ignores it, depending on the Scan Re-
sume function, the VSC function or the squelch sta-
tus.
!
0
Push [PRO](F-1) to cancel the scan.
Programmed scan/Fine programmed scan (VFO mode)
D
About the Fine programmed scan
When a signal is received during Fine programmed
scan, the scanning tuning step is temporarily set to
10 Hz and the scan speed decreases.
q
Start the programmed scan.
• Follow steps
q
through
i
as described above.
w
While scanning, push [FIN](F-3) to switch the scan
function between a programmed scan and a Fine
programmed scan.
e
Push [PRO](F-1) to cancel the scan.
[SCAN]/[PRO]
[VFO/MEMO] [TS]
[MENU]
[RF/SQL]
Mode switches
PRO
F
SPAN
SET
FIN
SCAN
PROG
SCAN:P2
SCAN
MEM
SWR
TCON
VSC
M2
PRO
F
SPAN
SET
FIN
SCAN
PROG:P1
F
:
±
10k
PRO
F
SPAN
SET
FIN
SCAN
PROG:P2
F
:
±
10k
Hold down
While Programmed scanning
PRO
F
SPAN
SET
FIN
SCAN
PROG
SCAN:P2
PRO
F
SPAN
SET
FIN
SCAN
F-PROG
SCAN:P2
While Fine programmed scanning
Push
Push
Push