Intel SR2400SYSD2 User Guide - Page 100
Installing the Fixed Drive Air Baffle, Installing a Hot-swap Power
UPC - 735858169172
View all Intel SR2400SYSD2 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 100 highlights
12. Set the replacement power supply distribution module into the chassis and slide it backward against the power supply. See letters "A" and "B" in the figure below. 13. Push down on the lever at the front of the power distribution the power supply distribution module while lining up the holes on power supply stands on chassis. See letter "C" Press down until power supply sits firmly in place. B A C TP01353 * Air baffle not shown for illustrative purposes. Figure 68. Installing the Power Distribution Module 14. Connect the main power, CPU power, and power signal from the power supply to the server board. Refer back to Figure 64 and see your server board documentation to locate the connection points for these cables. 15. Install the air baffle. For instructions on installing the baffle and you have hot-swap drives installed, see "Installing the Large Hot-swap Air Baffle (Backplane Installed)." For instructions on installing the baffle if you are using fixed drives, see "Installing the Fixed Drive Air Baffle (No Backplane Installed)." 16. (Hot-swap system only): Connect the 2x3 power cable to the backplane. Refer back to Figure 65 for a diagram of this connection point. 17. (Fixed drive system only): Connect the 2x3 power cable to the SATA power adapter cable Refer back to Figure 66 to see how these cables connect. 18. (Hot-swap system only): Connect the flex cable to the server. Refer back to Figure 63 and see your server board documentation to locate the connection points for this cable. 19. Install the hot-swap power supply/supplies. For instructions, see "Installing a Hot-swap Power Supply." 20. Install the PCI riser assembly. For instructions, see "Installing the PCI Riser Assembly." 76