Intel SR2400SYSD2 User Guide - Page 103

Disconnecting the Power Cables from the Server Board, Disconnecting

Page 103 highlights

Hardware Installations and Upgrades 8. Unplug the main power, power signal and CPU power cables from the server board. The position of your cables may be different. See your server board documentation to locate the connection points. In the diagram below, letter "A" shows the main power cable, letter "B" shows the power signal cable, and letter "C" shows the CPU power cable. B A C Figure 70. Disconnecting the Power Cables from the Server Board 9. (Hot-swap system only): Disconnect the 2x3 power cable from the backplane. See the figure below. For assistance in locating connectors on the SATA or SCSI backplane, see "Hot-Swap SATA Backplane Connections" or "Hot-Swap SCSI Backplane Connections." TP01350 Figure 71. Disconnecting the Power Cable from the Backplane Intel® Server Chassis SR2400/SR2400DC User Guide 79

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139

Hardware Installations and Upgrades
Intel® Server Chassis SR2400/SR2400DC User Guide
79
8.
Unplug the main power, power signal and CPU power cables from the server board. The
position of your cables may be different. See your server board documentation to locate the
connection points. In the diagram below, letter “A” shows the main power cable, letter “B”
shows the power signal cable, and letter “C” shows the CPU power cable.
C
B
A
Figure 70.
Disconnecting the Power Cables from the Server Board
9.
(Hot-swap system only): Disconnect the 2x3 power cable from the backplane. See the figure
below. For assistance in locating connectors on the SATA or SCSI backplane, see “
Hot-Swap
SATA Backplane
Connections” or “
Hot-Swap SCSI Backplane
Connections.”
TP01350
Figure 71.
Disconnecting the Power Cable from the Backplane