Toshiba M200-ST2002 Maintenance Manual - Page 141
Bluetooth, Tests and Diagnostics, Test fail, Table 3-2, Error code for NICSPC73.EXE 1/2
![]() |
View all Toshiba M200-ST2002 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 141 highlights
3.16 Bluetooth Test Figure 3-3 Test fail 3 Tests and Diagnostics 2. Messages when BD_ADDR is invalid are as follows: Message Invalid BD_ADDR (all 00) Invalid BD_ADDR (all FF) Invalid BD_ADDR (bit0=1) Invalid BD_ADDR (bit1=1) Invalid BD_ADDR (define in the file) Meaning 0x000000000000 0xFFFFFFFFFFFF bit40=1b bit41=1b BD_ADDR is the one already defined in the file. If the machine detects a malfunction, it indicates the error code as shown below. The error code begins with the least significant digit. Error code Table 3-2 Error code for NICSPC73.EXE (1/2) Error code Meaning 0x01 Unknown HCI Command. 0x02 No Connection. 0x03 Hardware Failure. 0x04 Page Timeout. 0x05 Authentication Failure. 0x06 Key Missing. 0x07 Memory Full. 0x08 Connection Timeout. 0x09 Max Number Of Connections. 0x0a Max Number Of SCO Connections To A Device. 0x0b ACL Connection already exists. 0x0c Command Disallowed. 0x0d Host Rejected due to limited resources. 0x0e Host Rejected due to security reasons. 0x0f Host Rejected due to remote device is only a personal device. 0x10 Host Timeout. 0x11 Unsupported Feature or Parameter Value. 0x12 Invalid HCI Command Parameters. 0x13 Other End Terminated Connection: Used Ended Connection. 0x14 Other End Terminated Connection: Low Resources. 0x15 Other End Terminated Connection: About to Power Off. 0x16 Connection Terminated by Local Host. 0x17 Repeated Attempts. 0x18 Paring Not Allowed. 0x19 Unknown LMP PDU. 0x1a Unsupported Remote Feature. Portege M200 Maintenance Manual (960-457) 3-39
![](/manual_guide/products/toshiba-m200st2001-maintenance-manual-c5b52ff/141.png)