Toshiba M200-ST2002 Maintenance Manual - Page 71
Procedure 3, Connector Check and Replacement Check, 5 FDD Troubleshooting, Troubleshooting
![]() |
View all Toshiba M200-ST2002 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 71 highlights
2.5 USB 3.5" FDD Troubleshooting 2 Troubleshooting Procedure 3 Connector Check and Replacement Check The USB FDD connector may be disconnected from the connector on the system board. Check visually that the connector is connected firmly. Check 1 Make sure the USB FDD cable is firmly connected to the PJ4600 or PJ4601 of the system board. USB FDD System board PJ4600 or PJ4601 If any of the connections are loose, reconnect firmly and repeat Procedure 2. If there is still an error, go to Check 2. Check 2 The USB FDD may be defective or damaged. Replace it with a new one. If the FDD is still not functioning properly, perform Check 3. Check 3 Replace the system board with a new one following the steps in Chapter 4, Replacement Procedures. Portege M200 Maintenance Manual (960-457) 2-33