Toshiba M200-ST2002 Maintenance Manual - Page 87
Procedure 3, Connector/Replacement Check, Tablet
![]() |
View all Toshiba M200-ST2002 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 87 highlights
2.14 Tablet Pen Troubleshooting 2 Troubleshooting Procedure 3 Connector/Replacement Check The Digitizer and LCD are connected to the system board as below. System board PJ3540 PJ5205, PJ5206 Digitizer LCD Check 1 The Digitizer might not be connected. Make sure the Digitizer is connected to the PJ3540 on the system board. If there is still an error, go to Check 2. Check 2 The LCD might not be connected. Make sure the LCD is connected to the PJ5205 and PJ5206 on the system board. If there is still an error, go to Check 3. Check 3 The Digitizer, the LCD or the system board might be defective. Replace it with a new one following the steps in Chapter 4. Then check the tablet pen is working properly. Portege M200 Maintenance Manual (960-457) 2-49
![](/manual_guide/products/toshiba-m200st2001-maintenance-manual-c5b52ff/87.png)