Cisco 2950 Hardware Installation Guide - Page 94
Environmental Ranges, Power Requirements, Physical Dimensions, Table A-5
UPC - 746320454504
View all Cisco 2950 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 94 highlights
Appendix A Technical Specifications 1. This switch meets ASTM D3332. 2. RPS = redundant power system Table A-5 Technical Specifications for Catalyst-2950ST-24 997 LRE Switches Environmental Ranges Operating temperature Storage temperature Operating humidity Operating altitude Storage altitude Shock Power Requirements Power consumption Power rating DC input voltage Wire gauge for power connection Branch circuit protection Physical Dimensions Weight Dimensions (H x W x D) 1. This switch meets ASTM D3332. 2. AWG = American Wire Gauge 32 to 113°F (0 to 45°C) -13 to 158°F (-25 to 70°C) 10 to 85% (noncondensing) Up to 10,000 ft (3000 m) Up to 15,000 ft (4570 m) 84 in. per sec (2.13 m per sec)1 50W (maximum) 171 Btus per hour 0.083 kVA -36 to -72 VDC 18 AWG2 (6 AWG for protective earth) 5 A 8 lb (3.6 kg) 1.73 x 17.5 x 9.96 in. (4.36 x 44.45 x 24.18 cm) Catalyst 2950 Switch Hardware Installation Guide A-4 OL-6156-01