IBM 8840 Hardware Maintenance Manual - Page 98
Management
UPC - 000435863799
View all IBM 8840 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 98 highlights
Note: See "System" on page 108 to determine which components a field service technician should replace. Error code/symptom FRU/action 166-407-001 System Management: Failed 1. Disconnect all server and option power cords from the server, (BMC indicates failure in I2C bus test.) wait 30 seconds, reconnect, and retry. 2. Reflash or update firmware for BMC. 3. Operator information panel cable. 4. Operator information panel. 5. System board. 166-NNN-001 System Management: Failed (BMC indicates failure in self test where NNN=300 to 320.) 1. Disconnect all server and option power cords from the server, wait 30 seconds, reconnect, and retry. 2. Reflash or update firmware for BMC. 3. System board. 166-NNN-001 System Management: 1. Disconnect all server and option power cords from the server, Failed (BMC indicates failure in I2C bus wait 30 seconds, reconnect, and retry. test where NNN=400 to 420 (excluding 412, 414, and 415).) 2. Reflash or update firmware for BMC. 3. System board. 166-412-001 System Management: Failed 1. Disconnect all server and option power cords from the server, (BMC indicates failure in I2C bus test wait 30 seconds, reconnect, and retry. where NNN=400 to 420) 2. Reflash or update firmware for BMC. 3. Power backplane 4. System board. 166-414-001 System Management: Failed 1. Disconnect all server and option power cords from the server, (BMC indicates failure in I2C bus test wait 30 seconds, reconnect, and retry. where NNN=400 to 420) 2. Reflash or update firmware for BMC. 3. SCSI cable 4. SCSI backplane 5. System board. 166-415-001 System Management: Failed 1. Disconnect all server and option power cords from the server, (BMC indicates failure in I2C bus test wait 30 seconds, reconnect, and retry. where NNN=400 to 420) 2. Reflash or update firmware for BMC. 3. Operator panel cable 4. Operator panel 5. System board. 180-XXX-000 (Diagnostics LED failure) Run diagnostics panel LED test for the failing LED. 180-XXX-001 (Failed front LED panel test) 1. Operator information panel 2. System board 180-XXX-002 (Failed diagnostics LED panel test) 1. Diagnostics panel 2. System board 180-361-003 (Failed fan LED test) 1. Fan (s) 2. System board 180-XXX-003 (Failed system board LED test) System board 180-XXX-005 (Failed SCSI backplane LED test) 1. SCSI backplane 2. SCSI backplane cable 3. System board 88 xSeries 346 Types 8840 and 1880: Hardware Maintenance Manual and Troubleshooting Guide