IBM 8840 Hardware Maintenance Manual - Page 99
termination.
UPC - 000435863799
View all IBM 8840 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 99 highlights
Note: See "System" on page 108 to determine which components a field service technician should replace. Error code/symptom FRU/action 201-XXX-0NN (Failed memory test.) Note: nn = slot of failing DIMM 1. Replace the DIMM is slot NN. 2. Processor board 3. Memory adapter, if installed. 201-XXX-N99 (Multiple DIMM failure, see error text) Note: n= is slot numbers of failing pair 1. See error text for failing DIMMs.N 2. Processor board 3. Memory adapter, if installed. 202-XXX-001 (Failed system cache test) 1. VRM 1 2. Microprocessor 1 202-XXX-002 (Failed system cache test) 1. VRM 2 2. Microprocessor 2 206-XXX-000 (Failed diskette drive test) 1. Rerun the test with a different diskette. 2. Cable. 3. Diskette drive. 4. System board. 215-XXX-000 (Failed IDE CD-ROM drive test) 1. Rerun the test with a different DVD-ROM drive. 2. DVD-ROM drive cables. 3. DVD-ROM drive. 4. System board. 217-198-XXX (Could not establish drive parameters) 1. Check cable and termination. 2. SCSI backplane. 3. Hard disk. 217-XXX-000 (Failed BIOS hard disk test) Note: If RAID is configured, the hard disk number refers to the RAID logical array. Hard disk 1 217-XXX-001 (Failed BIOS hard disk test) Note: If RAID is configured, the hard disk number refers to the RAID logical array. Hard disk 2 217-XXX-002 (Failed BIOS hard disk test) Note: If RAID is configured, the hard disk number refers to the RAID logical array. Hard disk 3 217-XXX-003 (Failed BIOS hard disk test) Note: If RAID is configured, the hard disk number refers to the RAID logical array. Hard disk 4 217-XXX-004 (Failed BIOS hard disk test) Note: If RAID is configured, the hard disk number refers to the RAID logical array. Hard disk 5 217-XXX-005 (Failed BIOS hard disk test) Note: If RAID is configured, the hard disk number refers to the RAID logical array Hard disk 6 Chapter 6. Symptom-to-FRU index 89