Scan resume condition

Page 96 highlights

11 SCAN OPERATION Scan resume condition [ The scan resume condition can be selected as timer or pause scan. The selected resume condition is also used for priority watch. (pgs. 86, 87) D Setting from the application q Display the Set Mode screen. - Select "Edit Set Mode(C)..." in View menu. - Click " " in tool bar. - Press [F7] key on the PC keyboard. wDouble click the "Scan Resume Timer" cell, then select the desired scan resume condition from "P-2," "T-5," "T-10" and "T-15." • Resuming conditions • "P-2" : Scan pauses until the signal disappears and then resumes 2 sec. later. • "T-5" : Scan pauses 5 sec. while receiving a signal. • "T10" : Scan pauses 10 sec. while receiving a signal. • "T-15" : Scan pauses 15 sec. while receiving a signal. eTo close the Set Mode screen, click " " in tool bar or click " ." D Setting from the RC-24 q Push [TXinh• ] for 0.5 sec. to enter set mode. wPush [MODE] or [TXinh• ] several times to select "Scan Timer" item. • Select "ON" for "Extension" item in advance. [TXinh• ] [MODE] Double click then select the desired scan resume condition. T-10 Scan Timer e Rotate [DIAL] to select the desired scan resume condition. • See "•Resuming conditions" above. r Push [PWR] momentarily to exit set mode. 89

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124

89
11
SCAN OPERATION
Scan resume condition
[
The scan resume condition can be selected as timer or pause
scan. The selected resume condition is also used for priority
watch. (pgs. 86, 87)
D
Setting from the application
q
Display the Set Mode screen.
- Select
Edit Set Mode(C
)...
in View menu.
- Click
in tool bar.
- Press [F7] key on the PC keyboard.
w
Double click the
Scan Resume Timer
cell, then select the
desired scan resume condition from
P-2,
T-5,
T-10
and
T-15.
• Resuming conditions
•“
P-2
: Scan pauses until the signal disappears and then re-
sumes 2 sec. later.
•“
T-5
: Scan pauses 5 sec. while receiving a signal.
•“
T10
: Scan pauses 10 sec. while receiving a signal.
•“
T-15
: Scan pauses 15 sec. while receiving a signal.
e
To close the Set Mode screen, click
in tool bar or click
.
D
Setting from the RC-24
q
Push [TXinh
] for 0.5 sec. to enter set mode.
w
Push [MODE] or [TXinh
] several times to select
Scan
Timer
item.
Select
ON
for
Extension
item in advance.
e
Rotate [DIAL] to select the desired scan resume condition.
See
•Resuming conditions
above.
r
Push [PWR] momentarily to exit set mode.
Scan
Timer
T-10
[MODE]
[TXinh
]
Double click
then select the desired
scan resume condition.