Statistics, Plot1, STAT PLOTS, Xlist:L1, ZoomStat, LinRegax+b, STAT CALC
View all Texas Instruments TI-84 PLUS SILV manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 186 highlights
4. Press 6 Ë 5 Í to store the first pendulum string length (6.5 cm) in L1. The rectangular cursor moves to the next row. Repeat this step to enter each of the 12 string length values in the table. 5. Press ~ to move the rectangular cursor to the first row in L2. Press Ë 51 Í to store the first time measurement (.51 sec) in L2. The rectangular cursor moves to the next row. Repeat this step to enter each of the 12 time values in the table. 6. Press o to display the Y= editor. If necessary, press ' to clear the function Y1. As necessary, press }, Í, and ~ to turn off Plot1, Plot2, and Plot3 from the top line of the Y= editor (Chapter 3). As necessary, press †, |, and Í to deselect functions. 7. Press y , 1 to select 1:Plot1 from the STAT PLOTS menu. The stat plot editor is displayed for plot 1. 8. Press Í to select On, which turns on plot 1. Press † Í to select " (scatter plot). Press † y d to specify Xlist:L1 for plot 1. Press † y e to specify Ylist:L2 for plot 1. Press † ~ Í to select + as the Mark for each data point on the scatter plot. 9. Press q 9 to select 9:ZoomStat from the ZOOM menu. The window variables are adjusted automatically, and plot 1 is displayed. This is a scatter plot of the time-versus-length data. Since the scatter plot of time-versus-length data appears to be approximately linear, fit a line to the data. 10. Press ... ~ 4 to select 4:LinReg(ax+b) (linear regression model) from the STAT CALC menu. Chapter 12: Statistics 179