:command (while condition is true) :End :command Program Output Repeat Repeat repeats a group of commands until condition is true (nonzero). It is similar to While, but condition is tested when End is encountered; therefore, the group of commands is always executed at least once. Repeat instructions can be nested. :Repeat condition :command (until condition is true) :command (until condition is true) :End :command Program Output End End identifies the end of a group of commands. You must include an End instruction at the end of each For(, While, or Repeat loop. Also, you must paste an End instruction at the end of each If-Then group and each If-Then-Else group. Pause Pause suspends execution of the program so that you can see answers or graphs. During the pause, the pause indicator is on in the top-right corner. Press Í to resume execution. • Pause without a value temporarily pauses the program. If the DispGraph or Disp instruction has been executed, the appropriate screen is displayed. • Pause with value displays value on the current home screen. value can be scrolled. Chapter 16: Programming 284