Dell PowerConnect J-SRX100 Hardware Guide - Page 38

Clearance Requirements for Airflow and Hardware Maintenance of the J-SRX100 Services Gateway

Page 38 highlights

PowerConnect J-SRX100 Services Gateway Hardware Guide Table 13: Rack Requirements for the Services Gateway Rack Requirements Specifications Rack Size A 19 in. (48.3 cm) rack as defined in Cabinets, Racks, Panels, and Associated Equipment (document number EIA-310-D) published by the Electronics Industry Association (http://www.eia.org). Rack Requirements • The outer edges of the mounting brackets extend the width of either chassis to 19 in. (48.3 cm). • The front of the chassis extends approximately 0.5 in. (1.27 cm) beyond the mounting ears. • Maximum permissible ambient temperature when two devices are placed side by side in a 19 in. rack is 40°C. Spacing of Mounting Bracket and Flange Holes • The holes within each rack set are spaced at 1 U [1.75 in. (4.5 cm)]. The device can be mounted in any rack that provides holes or hole patterns spaced at 1-U [1.75 in. (4.5 cm)] increments. • The mounting brackets and front-mount flanges used to attach the chassis to a rack are designed to fasten to holes spaced at rack distances of 1 U (1.75 in.). • The mounting holes in the mounting brackets provided with the device are spaced 1.25 in. (3.2 cm) apart (top and bottom mounting hole). Connecting to the Building Structure Always secure the rack in which you are installing the services gateway to the structure of the building. If your geographical area is subject to earthquakes, bolt the rack to the floor. For maximum stability, also secure the rack to ceiling brackets. Related • General Site Guidelines for Installing the J-SRX100 Services Gateway on page 22 Documentation • Site Preparation Checklist for the J-SRX100 Services Gateway on page 19 • J-SRX100 Services Gateway Cabinet Requirements on page 22 • Clearance Requirements for Airflow and Hardware Maintenance of the J-SRX100 Services Gateway on page 24 Clearance Requirements for Airflow and Hardware Maintenance of the J-SRX100 Services Gateway When planning the installation site for the J-SRX100 Services Gateway, you need to allow sufficient clearance around the device. When planning the installation site for the services gateway, consider the following: • For the operating temperature of the services gateway to be optimal, the airflow around the chassis must be unrestricted. • For service personnel to remove and install hardware components, there must be adequate space at the front and back of the device. Allow at least 24 in. (61 cm) both in front of and behind the device. 24

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158

Table 13: Rack Requirements for the Services Gateway
Specifications
Rack Requirements
A 19 in. (48.3 cm) rack as defined in
Cabinets, Racks, Panels, and
Associated Equipment
(document number EIA-310-D) published by the
Electronics Industry Association (
).
Rack Size
The outer edges of the mounting brackets extend the width of either
chassis to 19 in. (48.3 cm).
The front of the chassis extends approximately 0.5 in. (1.27 cm) beyond
the mounting ears.
Maximum permissible ambient temperature when two devices are
placed side by side in a 19 in. rack is 40°C.
Rack Requirements
The holes within each rack set are spaced at 1 U [1.75 in. (4.5 cm)].
The device can be mounted in any rack that provides holes or hole
patterns spaced at 1-U [1.75 in. (4.5 cm)] increments.
The mounting brackets and front-mount flanges used to attach the
chassis to a rack are designed to fasten to holes spaced at rack
distances of 1 U (1.75 in.).
The mounting holes in the mounting brackets provided with the device
are spaced 1.25 in. (3.2 cm) apart (top and bottom mounting hole).
Spacing of Mounting
Bracket and Flange
Holes
Always secure the rack in which you are installing the services gateway
to the structure of the building. If your geographical area is subject to
earthquakes, bolt the rack to the floor. For maximum stability, also secure
the rack to ceiling brackets.
Connecting to the
Building Structure
Related
Documentation
General Site Guidelines for Installing the J-SRX100 Services Gateway on page 22
Site Preparation Checklist for the J-SRX100 Services Gateway on page 19
J-SRX100 Services Gateway Cabinet Requirements on page 22
Clearance Requirements for Airflow and Hardware Maintenance of the J-SRX100
Services Gateway on page 24
Clearance Requirements for Airflow and Hardware Maintenance of the J-SRX100
Services Gateway
When planning the installation site for the J-SRX100 Services Gateway, you need to allow
sufficient clearance around the device.
When planning the installation site for the services gateway, consider the following:
For the operating temperature of the services gateway to be optimal, the airflow around
the chassis must be unrestricted.
For service personnel to remove and install hardware components, there must be
adequate space at the front and back of the device. Allow at least 24 in. (61 cm) both
in front of and behind the device.
24
PowerConnect J-SRX100 Services Gateway Hardware Guide