Page 112 highlights
Description FRU/action The Ethernet link status v Make sure that the hub/switch is turned on. LED does not work. v Check all connections at the Ethernet controller and the hub/switch. v Use another port on the hub/switch. v If the hub/switch does not support auto-negotiation, manually configure the Ethernet controller to match the hub/switch. v If you manually configured the Duplex mode, make sure that you also manually configure the speed. The Ethernet v Make sure that you have installed the network device drivers. transmit/receive activity v The network might be idle. Try sending data from this server. LED does not work. Data is incorrect or sporadic. v Make sure that you are using Category 5 or higher cabling when operating the server at 100 Mbps or at 1000 Mbps. v Make sure that the cables do not run close to noise-inducing sources like fluorescent lights. The Ethernet controller stopped working when another adapter was added to the server. v Make sure that the cable is connected to the Ethernet controller. v Make sure that the PCI system BIOS code is current. v Reseat the adapter. v Determine whether the interrupt (IRQ) setting that is assigned to the Ethernet adapter is also assigned to another device in the system. Use the Configuration/Setup Utility program to determine whether this is the case. Although interrupt sharing is allowed for PCI devices, some devices do not function well when they share an interrupt with a dissimilar PCI device. Try changing the IRQ that is assigned to the Ethernet adapter or the other device. v Reseat or replace the adapter. The Ethernet controller v Try a different port on the hub/switch. stopped working without v Reinstall the device drivers. See the operating-system documentation and the apparent cause. ServerGuide information. Ethernet controller messages The integrated Ethernet controller might display messages from certain device drivers. The latest available information concerning these messages is at the IBM Support Web site at http://www.ibm.com/support/. 102 xSeries 236 Type 8841: Hardware Maintenance Manual and Troubleshooting Guide