IBM 88410EU User Manual - Page 120

code/symptom

Page 120 highlights

Note: See "System replaceable units" on page 144 to determine which components should be replaced by a field service technician. Error code/symptom FRU/action 201 1. (Memory test error.) If the server does not have the latest level of BIOS installed, 2. update the BIOS to the latest level and run the diagnostic program again. DIMM System board 229 (Cache error) 1. Microprocessor 2. Optional microprocessor (if installed) 262 (DRAM parity configuration error) 1. Run the Configuration/Setup Utility program. 2. Battery. 3. System board. 289 (DIMM disabled by POST or user) 1. Run the Configuration/Setup Utility program, if the DIMM was disabled by the user. 2. Disabled DIMM, if not disabled by user. 301 (Keyboard or keyboard controller error) 1. Keyboard 2. System board 303 (Keyboard controller error) v System board 602 (Invalid diskette boot record) 1. Diskette 2. Diskette drive 3. Cable 4. System board 604 (Diskette drive error) 1. Run the Configuration/Setup Utility program and diagnostics. 2. Diskette drive. 3. Drive cable. 4. System board. 605 (Unlock failure) 1. Diskette drive 2. Drive cable 3. System board 662 (Diskette drive configuration error) 1. Run the Configuration/Setup Utility program and diagnostics. 2. Diskette drive. 3. Drive cable. 4. System board. 762 (Coprocessor configuration error) 1. Run the Configuration/Setup Utility program. 2. Battery. 3. Microprocessor. 962 (Parallel port error) 1. Disconnect the external cable on the parallel port. 2. Run the Configuration/Setup Utility program. 3. System board. 11XX (System board serial port 1 or 2 error) 1. Disconnect the external cable on the serial port. 2. Run the Configuration/Setup Utility program. 3. System board. 110 xSeries 236 Type 8841: Hardware Maintenance Manual and Troubleshooting Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210

Note:
See
“System
replaceable
units”
on
page
144
to
determine
which
components
should
be
replaced
by
a
field
service
technician.
Error
code/symptom
FRU/action
201
(Memory
test
error.)
If
the
server
does
not
have
the
latest
level
of
BIOS
installed,
update
the
BIOS
to
the
latest
level
and
run
the
diagnostic
program
again.
1.
DIMM
2.
System
board
229
(Cache
error)
1.
Microprocessor
2.
Optional
microprocessor
(if
installed)
262
(DRAM
parity
configuration
error)
1.
Run
the
Configuration/Setup
Utility
program.
2.
Battery.
3.
System
board.
289
(DIMM
disabled
by
POST
or
user)
1.
Run
the
Configuration/Setup
Utility
program,
if
the
DIMM
was
disabled
by
the
user.
2.
Disabled
DIMM,
if
not
disabled
by
user.
301
(Keyboard
or
keyboard
controller
error)
1.
Keyboard
2.
System
board
303
(Keyboard
controller
error)
v
System
board
602
(Invalid
diskette
boot
record)
1.
Diskette
2.
Diskette
drive
3.
Cable
4.
System
board
604
(Diskette
drive
error)
1.
Run
the
Configuration/Setup
Utility
program
and
diagnostics.
2.
Diskette
drive.
3.
Drive
cable.
4.
System
board.
605
(Unlock
failure)
1.
Diskette
drive
2.
Drive
cable
3.
System
board
662
(Diskette
drive
configuration
error)
1.
Run
the
Configuration/Setup
Utility
program
and
diagnostics.
2.
Diskette
drive.
3.
Drive
cable.
4.
System
board.
762
(Coprocessor
configuration
error)
1.
Run
the
Configuration/Setup
Utility
program.
2.
Battery.
3.
Microprocessor.
962
(Parallel
port
error)
1.
Disconnect
the
external
cable
on
the
parallel
port.
2.
Run
the
Configuration/Setup
Utility
program.
3.
System
board.
11XX
(System
board
serial
port
1
or
2
error)
1.
Disconnect
the
external
cable
on
the
serial
port.
2.
Run
the
Configuration/Setup
Utility
program.
3.
System
board.
110
xSeries
236
Type
8841:
Hardware
Maintenance
Manual
and
Troubleshooting
Guide