IBM HS12 Service Guide - Page 123

IBM HS12 - BladeCenter - 8028 Manual

Page 123 highlights

v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 4, "Parts listing, Types 8014, 8028 and 1916," on page 25 to determine which components are CRUs and which components are FRUs. v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a trained service technician. Error code Description Action 00151720 Parity Error Reseat the microprocessor. Detected on Processor bus. 1. (Trained service technician only) Reseat the microprocessor - See "Removing a microprocessor and heat sink" on page 60 and "Installing a microprocessor and heat sink" on page 62. 2. Replace the following components one at a time, in the order shown, restarting the blade server each time: a. (Trained service technician only) Microprocessor - See "Removing a microprocessor and heat sink" on page 60 and "Installing a microprocessor and heat sink" on page 62. b. (Trained service technician only) System-board assembly - See "Removing the system-board assembly" on page 65 and "Installing the system-board assembly" on page 66. 00151730 CRC Error Reseat all DIMMs - See "Removing a memory module" on page 44 and "Installing a memory module" on page 46. 01295085 ECC checking hardware test failed 1. (Trained service technician only) Reseat the microprocessor - See "Removing a microprocessor and heat sink" on page 60 and "Installing a microprocessor and heat sink" on page 62. 2. Replace the following components, one at a time, in the order shown, restarting the blade server each time: a. (Trained service technician only) Microprocessor - See "Removing a microprocessor and heat sink" on page 60 and "Installing a microprocessor and heat sink" on page 62. b. (Trained service technician only) System-board assembly - See "Removing the system-board assembly" on page 65 and "Installing the system-board assembly" on page 66. 012980xx The BIOS does not support the Processor Pxx 1. Make sure that the microprocessor is supported. 2. Update the blade server firmware. Go to http://www.ibm.com/systems/support/. Chapter 6. Diagnostics 111

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204

v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v
See Chapter 4, “Parts listing, Types 8014, 8028 and 1916,” on page 25 to determine which components are CRUs
and which components are FRUs.
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Error code
Description
Action
00151720
Parity Error Reseat the microprocessor.
Detected on Processor bus.
1.
(Trained service technician only) Reseat the
microprocessor - See “Removing a
microprocessor and heat sink” on page 60 and
“Installing a microprocessor and heat sink” on
page 62.
2.
Replace the following components one at a time,
in the order shown, restarting the blade server
each time:
a.
(Trained service technician only)
Microprocessor - See “Removing a
microprocessor and heat sink” on page 60 and
“Installing a microprocessor and heat sink” on
page 62.
b.
(Trained service technician only)
System-board assembly - See “Removing the
system-board assembly” on page 65 and
“Installing the system-board assembly” on
page 66.
00151730
CRC Error
Reseat all DIMMs - See “Removing a memory
module” on page 44 and “Installing a memory
module” on page 46.
01295085
ECC checking hardware test failed
1.
(Trained service technician only) Reseat the
microprocessor - See “Removing a
microprocessor and heat sink” on page 60 and
“Installing a microprocessor and heat sink” on
page 62.
2.
Replace the following components, one at a time,
in the order shown, restarting the blade server
each time:
a.
(Trained service technician only)
Microprocessor - See “Removing a
microprocessor and heat sink” on page 60 and
“Installing a microprocessor and heat sink” on
page 62.
b.
(Trained service technician only)
System-board assembly - See “Removing the
system-board assembly” on page 65 and
“Installing the system-board assembly” on
page 66.
012980
xx
The BIOS does not support the Processor
P
xx
1.
Make sure that the microprocessor is supported.
2.
Update the blade server firmware. Go to
Chapter 6. Diagnostics
111