IBM HS12 Service Guide - Page 85

See Parts listing, Types 8014, 8028 and 1916

Page 85 highlights

v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 4, "Parts listing, Types 8014, 8028 and 1916," on page 25 to determine which components are CRUs and which components are FRUs. v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a trained service technician. Beep code Description Action 2-3-1 Screen initialization failed. (Trained service technician only) Replace the system-board assembly. See "Removing the system-board assembly" on page 65 and "Installing the system-board assembly" on page 66. 2-4-4 Unsupported memory configuration. 1. Check the DIMM error LEDs on the blade server. See "Light path diagnostics LEDs" on page 130 for more information. 2. Check the management-module event log for DIMM error messages. See "Error logs" on page 76. 3. Replace noncompatible or failing DIMMs in the blade server. See "Removing a memory module" on page 44and "Installing a memory module" on page 46. 3-1-1 Timer tick interrupt failed. (Trained service technician only) Replace the system-board assembly. See "Removing the system-board assembly" on page 65 and "Installing the system-board assembly" on page 66. 3-1-2 Interval timer channel 2 failed. (Trained service technician only) Replace the system-board assembly. See "Removing the system-board assembly" on page 65 and "Installing the system-board assembly" on page 66. 3-1-4 Time-of-day clock failed. 1. Reseat the battery. See "Removing the battery" on page 57 and "Installing the battery" on page 58. 2. Replace the following components one at a time, in the order shown, restarting the blade server each time: a. Battery - See "Removing the battery" on page 57 and "Installing the battery" on page 58. b. (Trained service technician only) System-board assembly - See "Removing the system-board assembly" on page 65 and "Installing the system-board assembly" on page 66. 3-2-1 Serial port failed. (Trained service technician only) Replace the system-board assembly. See "Removing the system-board assembly" on page 65 and "Installing the system-board assembly" on page 66. Chapter 6. Diagnostics 73

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204

v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v
See Chapter 4, “Parts listing, Types 8014, 8028 and 1916,” on page 25 to determine which components are CRUs
and which components are FRUs.
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Beep code
Description
Action
2-3-1
Screen initialization failed.
(Trained service technician only) Replace the
system-board assembly. See “Removing the
system-board assembly” on page 65 and
“Installing the system-board assembly” on
page 66.
2-4-4
Unsupported memory configuration.
1.
Check the DIMM error LEDs on the blade
server. See “Light path diagnostics LEDs”
on page 130 for more information.
2.
Check the management-module event log
for DIMM error messages. See “Error logs”
on page 76.
3.
Replace noncompatible or failing DIMMs in
the blade server. See “Removing a memory
module” on page 44and “Installing a
memory module” on page 46.
3-1-1
Timer tick interrupt failed.
(Trained service technician only) Replace the
system-board assembly. See “Removing the
system-board assembly” on page 65 and
“Installing the system-board assembly” on
page 66.
3-1-2
Interval timer channel 2 failed.
(Trained service technician only) Replace the
system-board assembly. See “Removing the
system-board assembly” on page 65 and
“Installing the system-board assembly” on
page 66.
3-1-4
Time-of-day clock failed.
1.
Reseat the battery. See “Removing the
battery” on page 57 and “Installing the
battery” on page 58.
2.
Replace the following components one at a
time, in the order shown, restarting the
blade server each time:
a.
Battery - See “Removing the battery” on
page 57 and “Installing the battery” on
page 58.
b.
(Trained service technician only)
System-board assembly - See “Removing
the system-board assembly” on page 65
and “Installing the system-board
assembly” on page 66.
3-2-1
Serial port failed.
(Trained service technician only) Replace the
system-board assembly. See “Removing the
system-board assembly” on page 65 and
“Installing the system-board assembly” on
page 66.
Chapter 6. Diagnostics
73