IBM HS12 Service Guide - Page 143
Lit light path, diagnostics LED
![]() |
UPC - 883436037129
View all IBM HS12 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 143 highlights
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 4, "Parts listing, Types 8014, 8028 and 1916," on page 25 to determine which components are CRUs and which components are FRUs. v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a trained service technician. Lit light path diagnostics LED Description Action Microprocessor error The microprocessor has failed or overheated, or the start microprocessor is missing. 1. Check the advanced management module (AMM) log for more information. See "Using the Configuration/Setup Utility program" on page 15. 2. If the log shows that a microprocessor is disabled or that a microprocessor IERR has occurred, perform one of the following actions: a. (Trained service technician only) Reseat the microprocessor that is indicated by the lit LED. See "Removing a microprocessor and heat sink" on page 60 and "Installing a microprocessor and heat sink" on page 62. b. (Trained service technician only) Replace the microprocessor that is indicated by the lit LED. See "Removing a microprocessor and heat sink" on page 60 and "Installing a microprocessor and heat sink" on page 62. NMI (NMI error) The system board has failed. 1. Replace the blade server cover, reinsert the blade server in the BladeCenter unit, and then restart the blade server. Check the BMC log for information about the error. See "Using the Configuration/Setup Utility program" on page 15. 2. (Trained service technician only) Replace the system-board assembly - See "Removing the system-board assembly" on page 65 and "Installing the system-board assembly" on page 66. S BRD (System board error) The system board has failed (Trained service technician only) Replace the system-board assembly - See "Removing the system-board assembly" on page 65 and "Installing the system-board assembly" on page 66. TEMP (Over The system temperature has exceeded a temperature error) threshold level. 1. Check the function of the shared BladeCenter unit resources. See "Solving shared BladeCenter resource problems" on page 167. 2. Make sure that the room temperature is not too high. See "Features and specifications" on page 6 for temperature information. Chapter 6. Diagnostics 131
![](/manual_guide/products/ibm-hs12-service-guide-b4c349d/143.png)