IBM HS12 Service Guide - Page 84
and which components are FRUs
![]() |
UPC - 883436037129
View all IBM HS12 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 84 highlights
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 4, "Parts listing, Types 8014, 8028 and 1916," on page 25 to determine which components are CRUs and which components are FRUs. v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a trained service technician. Beep code Description Action 1-3-2 First 64K RAM parity test failed. 1. Reseat the DIMMs. See "Removing a memory module" on page 44 and "Installing a memory module" on page 46. 2. Replace the following components one at a time, in the order shown, restarting the blade server each time: a. DIMMs - See "Removing a memory module" on page 44 and "Installing a memory module" on page 46. b. (Trained service technician only) System-board assembly - See "Removing the system-board assembly" on page 65 and "Installing the system-board assembly" on page 66. 2-1-1 Secondary DMA register test failed. (Trained service technician only) Replace the system-board assembly. See "Removing the system-board assembly" on page 65 and "Installing the system-board assembly" on page 66.. 2-1-2 Primary DMA register test failed. (Trained service technician only) Replace the system-board assembly. See "Removing the system-board assembly" on page 65 and "Installing the system-board assembly" on page 66. 2-1-3 Primary interrupt mask register test failed. (Trained service technician only) Replace the system-board assembly. See "Removing the system-board assembly" on page 65 and "Installing the system-board assembly" on page 66. 2-1-4 Secondary interrupt mask register test failed. (Trained service technician only) Replace the system-board assembly. See "Removing the system-board assembly" on page 65 and "Installing the system-board assembly" on page 66. 2-2-2 Keyboard controller test failed. 1. Check the function of the shared BladeCenter unit resources (see "Solving shared BladeCenter resource problems" on page 167). 2. (Trained service technician only) Replace the system-board assembly. See "Removing the system-board assembly" on page 65 and "Installing the system-board assembly" on page 66. 72 BladeCenter HS12 Type 8014, 8028 or 1916: Problem Determination and Service Guide
![](/manual_guide/products/ibm-hs12-service-guide-b4c349d/84.png)