IBM HS12 Service Guide - Page 158

BSE-3 PCI-X A slot., the Firmware/VPD for this component.

Page 158 highlights

v See Chapter 4, "Parts listing, Types 8014, 8028 and 1916," on page 25 to determine which components are CRUs and which components are FRUs. v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a trained service technician. Error code Description Action 166-911-xxx Failed the BMC self test due to a failure in the 1. Turn off the blade server. See "Turning off the BSE-3 PCI-X A slot. blade server" on page 10. 2. Open the blade server release levers and pull the blade server away from the blade server bay, but do not remove it. See "Removing the blade server from the BladeCenter unit" on page 33. 3. Wait 45 seconds and reseat the blade server in the blade module bay and turn on the blade server. See "Installing the blade server in a BladeCenter unit" on page 34 and "Turning on the blade server" on page 9. 4. Rerun the test. See "Diagnostic tools overview" on page 67. 5. Make sure that the DSA Diagnostic code is up-to-date, upgrade if necessary; then, rerun the test. The latest code can be found on the IBM support Web site at http:// www.ibm.com/support/ docview.wss?uid=psg1SERV-DSA. 6. Make sure that the BMC firmware level is up-to-date, upgrade if necessary; then, rerun the test. The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware/VPD section for this component. The latest level firmware for this component can be found on the IBM support Web site at http://www.ibm.com/support/ docview.wss?uid=psg1MIGR-4JTS2T. 7. Turn off the blade server, open the blade server release levers and pull the blade server away from the blade server bay, but do not remove it from the bay. See "Removing the blade server from the BladeCenter unit" on page 33. 8. Wait 45 seconds and reseat the blade server in the blade module bay and turn on the blade server. See "Installing the blade server in a BladeCenter unit" on page 34 and "Turning on the blade server" on page 9. 9. Rerun the test. See "Diagnostic tools overview" on page 67. 10. If the failure remains, see Chapter 5, "Removing and replacing blade server components," on page 31. 146 BladeCenter HS12 Type 8014, 8028 or 1916: Problem Determination and Service Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204

v
See Chapter 4, “Parts listing, Types 8014, 8028 and 1916,” on page 25 to determine which components are CRUs
and which components are FRUs.
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Error code
Description
Action
166-911-xxx
Failed the BMC self test due to a failure in the
BSE-3 PCI-X A slot.
1.
Turn off the blade server. See “Turning off the
blade server” on page 10.
2.
Open the blade server release levers and pull
the blade server away from the blade server
bay, but do not remove it. See “Removing the
blade server from the BladeCenter unit” on
page 33.
3.
Wait 45 seconds and reseat the blade server in
the blade module bay and turn on the blade
server. See “Installing the blade server in a
BladeCenter unit” on page 34 and “Turning on
the blade server” on page 9.
4.
Rerun the test. See “Diagnostic tools overview”
on page 67.
5.
Make sure that the DSA Diagnostic code is
up-to-date, upgrade if necessary; then, rerun
the test. The latest code can be found on the
IBM support Web site at http://
www.ibm.com/support/
docview.wss?uid=psg1SERV-DSA.
6.
Make sure that the BMC firmware level is
up-to-date, upgrade if necessary; then, rerun
the test. The installed firmware level can be
found in the DSA Diagnostic Event Log within
the Firmware/VPD section for this component.
The latest level firmware for this component
can be found on the IBM support Web site at
docview.wss?uid=psg1MIGR-4JTS2T.
7.
Turn off the blade server, open the blade server
release levers and pull the blade server away
from the blade server bay, but do not remove it
from the bay. See “Removing the blade server
from the BladeCenter unit” on page 33.
8.
Wait 45 seconds and reseat the blade server in
the blade module bay and turn on the blade
server. See “Installing the blade server in a
BladeCenter unit” on page 34 and “Turning on
the blade server” on page 9.
9.
Rerun the test. See “Diagnostic tools overview”
on page 67.
10.
If the failure remains, see Chapter 5,
“Removing and replacing blade server
components,” on page 31.
146