HP BL260c HP BladeSystem c-Class Enclosure Troubleshooting Guide - Page 71
set enclosure PDU_type X, Step 4, Action
UPC - 883585668663
View all HP BL260c manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 71 highlights
Step Step 4 Step 5 Midplane assembly replacement action and verification Action Perform PDU part number update using the following OA CLI command: set enclosure PDU_type X In place of X, enter 1, 2, or 3, according to the power setup: • 1 for single-phase power • 2 for three-phase power, North America • 3 for three-phase power, international • 4 for DC power Action Install all server blades and interconnect modules in the original locations. Midplane assembly replacement 71
Midplane assembly replacement 71
Step
Midplane assembly replacement action and verification
Step 4
Action
Perform PDU part number update using the following OA CLI command:
set enclosure PDU_type X
In place of
X
, enter 1, 2, or 3, according to the power setup:
•
1 for single-phase power
•
2 for three-phase power, North America
•
3 for three-phase power, international
•
4 for DC power
Step 5
Action
Install all server blades and interconnect modules in the original locations.