HP P2000 HP P2000 G3 MSA System SMU Reference Guide - Page 135
Trap annotations are as follows, Recommended severity level for filtering: warning - msa array reference guide
View all HP P2000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 135 highlights
--#SUMMARY "Informational storage event # %d, type %d, description: %s" --#ARGUMENTS {0,1,2} --#SEVERITY INFORMATIONAL --#TIMEINDEX 6 ::= 3001 msaEventWarningTrap TRAP-TYPE ENTERPRISE hpMSA VARIABLES { connUnitEventId, connUnitEventType, connUnitEventDescr } DESCRIPTION "An event has been generated by the storage array. Recommended severity level (for filtering): warning" -- Trap annotations are as follows: --#TYPE "Warning storage event" --#SUMMARY "Warning storage event # %d, type %d, description: %s" --#ARGUMENTS {0,1,2} --#SEVERITY MINOR --#TIMEINDEX 6 ::= 3002 msaEventErrorTrap TRAP-TYPE ENTERPRISE hpMSA VARIABLES { connUnitEventId, connUnitEventType, connUnitEventDescr } DESCRIPTION "An event has been generated by the storage array. Recommended severity level (for filtering): error" -- Trap annotations are as follows: --#TYPE "Error storage event" --#SUMMARY "Error storage event # %d, type %d, description: %s" --#ARGUMENTS {0,1,2} --#SEVERITY MAJOR --#TIMEINDEX 6 ::= 3003 msaEventCriticalTrap TRAP-TYPE ENTERPRISE hpMSA VARIABLES { connUnitEventId, connUnitEventType, connUnitEventDescr } DESCRIPTION "An event has been generated by the storage array. Recommended severity level (for filtering): critical" -- Trap annotations are as follows: --#TYPE "Critical storage event" --#SUMMARY "Critical storage event # %d, type %d, description: %s" --#ARGUMENTS {0,1,2} --#SEVERITY CRITICAL --#TIMEINDEX 6 ::= 3004 END HP P2000 G3 MSA System SMU Reference Guide 135