Panasonic WJHD500A WJHD500A User Guide - Page 50

External Program Timer, Time Lapse Recording Internal, Timer, PROG1 - 4, SETUP/ESC, H or SF-A, 60FPS

Page 50 highlights

s External Program Timer The internal timer can be changed to the specified timer previously programmed by the input from the external timer. This function is enabled, when a contact is connected with pin 22 of the ALARM port. This item lets you enable or disable the external timer for recording. 1. Move the cursor to the EXT REC MODE parameter in the TIMER REC SETUP menu by pressing the D or C button. 2. Select the desired program to be changed by pressing the + or - button. PROG1 - 4: Selects a timer assigned program number. ---: Disables the external program timer. The factory default setting is ---. 3. Press the SET button to display the assigned program number menu previously programmed. If the program number menu has not been edited previously, edit the assigned program number menu as described before. 4. Press the SETUP/ESC button to return to the previous setup menu. s Time Lapse Recording (Internal Timer) These items let you set the recording parameters for Time Lapse Recording assigned in the program number menu. (Continued from Program Timer) 1. Select the recording mode T/L in the program number menu by pressing the + or - button, then press the SET button. The selected Time Lapse Recording menu shown below appears on the monitor screen. 3-1-1-1 PROG1-NO1-G1 REC SETUP T/L(TIME LAPSE) TIMER REC MODE REC RATE QUALITY TRIGGER ACTION EVENT REC MODE REC RATE(MAX) REC QUALITY DURATION DYNAMIC REC REC RATE(BASE) AUTO COPY SF- 24H 7.5FPS SUPER FINE REC+ALM SF- 24H 7.5FPS SUPER FINE 10S OFF 1FPS OFF 2. Move the cursor to the TIMER REC MODE parameter in the menu by pressing the D or C button. 3. Select the recording time mode to be set by pressing the + or - button. OFF: Disables normal recording and enables only alarm recording. SF-✽✽H or SF-A*✽✽H: Selects the recording time mode in enhanced fine quality. FQ-✽✽H or FQ-A*✽✽H: Selects the recording time mode in fine quality. NQ-✽✽H or NQ-A*✽✽H: Selects the recording time mode in normal quality. EX-✽✽H or EX-A*✽✽H: Selects the recording time mode in extended quality. SP or SP-A*: Freely selectable ✽✽ indicates the hours for recording time mode: 2, 12, 18, 24, 48, 72, 96, 120, 180, 240, 360, 480, 720, 960, 1200, 1440, 2160, 2880, 3600, 4320, 6480, 8640 (parameter A* indicates recording with audio) When the parameter SF/FQ/NQ/EX is selected for recording time, the recording rate and quality are automatically set according to the selected recording time. Note: It may not be possible to set the recording time, depending on the remaining storage capacity of the hard disk. The factory default setting is SF-24H. 4. If the parameter SP is selected for recording time, move the cursor to the REC RATE parameter by pressing the D or C button, then select a recording rate by pressing the + or - button. 1 - 60FPS: Records the selected number of freeze images every second. 0.5FPS: Records a freeze image every 2 seconds. 0.4FPS: Records a freeze image every 2.5 seconds. 0.3FPS: Records a freeze image every 3.3 seconds. 0.2FPS: Records a freeze image every 5 seconds. 0.1FPS: Records a freeze image every 10 seconds. Notes: • The maximum recording rate depends on the selected parameters in the COMMON SETUP menu as shown in the table. FIELD/FRAME FIELD FRAME 3DIM ON FRAME 3DIM OFF CAMERA GENLOCK ON OFF ON OFF ON OFF REC RATE 60FPS 30FPS 10FPS 10FPS 30FPS 15FPS 52

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102

52
External Program Timer
The internal timer can be changed to the specified timer
previously programmed by the input from the external
timer. This function is enabled, when a contact is connect-
ed with pin 22 of the ALARM port.
This item lets you enable or disable the external timer for
recording.
1. Move the cursor to the EXT REC MODE parameter in
the TIMER REC SETUP menu by pressing the
D
or
C
button.
2.
Select the desired program to be changed by pressing
the
+
or
-
button.
PROG1 - 4:
Selects a timer assigned program number.
---
:
Disables the external program timer.
The factory default setting is
---
.
3. Press the
SET
button to display the assigned program
number menu previously programmed.
If the program number menu has not been edited previ-
ously, edit the assigned program number menu as
described before.
4. Press the
SETUP/ESC
button to return to the previous
setup menu.
Time Lapse Recording (Internal
Timer)
These items let you set the recording parameters for Time
Lapse Recording assigned in the program number menu.
(Continued from Program Timer)
1. Select the recording mode T/L in the program number
menu by pressing the
+
or
-
button, then press the
SET
button.
The selected Time Lapse Recording menu shown
below appears on the monitor screen.
2.
Move the cursor to the TIMER REC MODE parameter in
the menu by pressing the
D
or
C
button.
3. Select the recording time mode to be set by pressing
the
+
or
-
button.
OFF:
Disables normal recording and enables only
alarm recording.
SF-
H or SF-A*
H:
Selects the recording time
mode in enhanced fine quality.
FQ-
H or FQ-A*
H:
Selects the recording time
mode in fine quality.
NQ-
H or NQ-A*
H:
Selects the recording time
mode in normal quality.
EX-
H or EX-A*
H:
Selects the recording time
mode in extended quality.
SP or SP-A*:
Freely selectable
indicates the hours for recording time mode:
2, 12, 18, 24, 48, 72, 96, 120, 180, 240, 360, 480,
720, 960, 1200, 1440, 2160, 2880, 3600, 4320,
6480, 8640
(parameter A* indicates recording with audio)
When the parameter SF/FQ/NQ/EX is selected for
recording time, the recording rate and quality are auto-
matically set according to the selected recording time.
Note:
It may not be possible to set the recording time,
depending on the remaining storage capacity of the
hard disk.
The factory default setting is SF-24H.
4.
If the parameter SP is selected for recording time, move
the cursor to the REC RATE parameter by pressing the
D
or
C
button, then select a recording rate by pressing
the
+
or
-
button.
1 - 60FPS:
Records the selected number of freeze
images every second.
0.5FPS:
Records a freeze image every 2 seconds.
0.4FPS:
Records a freeze image every 2.5 seconds.
0.3FPS:
Records a freeze image every 3.3 seconds.
0.2FPS:
Records a freeze image every 5 seconds.
0.1FPS:
Records a freeze image every 10 seconds.
Notes:
• The maximum recording rate depends on the
selected parameters in the COMMON SETUP menu
as shown in the table.
FIELD/FRAME
CAMERA GENLOCK
REC RATE
FIELD
ON
60FPS
OFF
30FPS
FRAME 3DIM
ON
10FPS
ON
OFF
10FPS
FRAME 3DIM
ON
30FPS
OFF
OFF
15FPS
3-1-1-1 PROG1-NO1-G1 REC SETUP
T/L(TIME LAPSE)
TIMER REC MODE
SF- 24H
REC RATE
7.5FPS
QUALITY
SUPER FINE
TRIGGER ACTION
REC+ALM
EVENT REC MODE
SF- 24H
REC RATE(MAX)
7.5FPS
REC QUALITY
SUPER FINE
DURATION
10S
DYNAMIC REC
OFF
REC RATE(BASE)
1FPS
AUTO COPY