D-Link DGS-1250 User Manual - Page 29

PoE System, System > PoE > PoE System, Usage Threshold, Policy Preempt, Trap State, Apply

Page 29 highlights

DGS-1250 Series Gigabit Ethernet Smart Managed Switch Web UI Reference Guide PoE System This window is used to configure the PoE system and display the detailed power information and PoE chip parameters for PoE modules. To view the following window, click System > PoE > PoE System, as shown below: Figure 3-10 PoE System Window The fields that can be configured for PoE System are described below: Parameter Usage Threshold Policy Preempt Trap State Description Enter the usage threshold to generate a log and send the corresponding standard notification. The range is from 1 to 99 percent. Select this option to enable or disable the disconnection of the Powered Device (PD) that is power-provisioned with a lower priority in order to release the power to the new connected PD with higher priority under power shortage conditions. Select this option to enable or disable the sending of PoE trap notifications. Click the Apply button to accept the changes made. Click the Show Detail button to see the PoE system Parameters table at the bottom of the window. After clicking the Show Detail button, the following window will appear. Figure 3-11 PoE System (Show Detail) Window 20

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263
  • 264
  • 265
  • 266
  • 267
  • 268
  • 269
  • 270
  • 271
  • 272
  • 273
  • 274
  • 275
  • 276
  • 277
  • 278
  • 279
  • 280
  • 281
  • 282
  • 283
  • 284
  • 285
  • 286
  • 287
  • 288
  • 289
  • 290
  • 291
  • 292
  • 293
  • 294
  • 295
  • 296
  • 297
  • 298
  • 299
  • 300
  • 301
  • 302
  • 303
  • 304
  • 305
  • 306
  • 307
  • 308
  • 309
  • 310
  • 311
  • 312
  • 313
  • 314
  • 315
  • 316
  • 317
  • 318
  • 319
  • 320

DGS-1250 Series Gigabit Ethernet Smart Managed Switch Web UI Reference Guide
20
PoE System
This window is used to configure the PoE system and display the detailed power information and PoE chip parameters
for PoE modules.
To view the following window, click
System > PoE > PoE System
, as shown below:
Figure 3-10 PoE System Window
The fields that can be configured for
PoE System
are described below:
Parameter
Description
Usage Threshold
Enter the usage threshold to generate a log and send the corresponding standard
notification. The range is from 1 to 99 percent.
Policy Preempt
Select this option to enable or disable the disconnection of the Powered Device
(PD) that is power-provisioned with a lower priority in order to release the power
to the new connected PD with higher priority under power shortage conditions.
Trap State
Select this option to enable or disable the sending of PoE trap notifications.
Click the
Apply
button to accept the changes made.
Click the
Show Detail
button to see the PoE system Parameters table at the bottom of the window.
After clicking the
Show Detail
button, the following window will appear.
Figure 3-11 PoE System (Show Detail) Window