See Getting Help on Table 1-1., Diagnostic Indicator Code, Causes, Corrective Action - memory configuration

Page 27 highlights

Table 1-1. Diagnostic Indicator Code (continued) Code Causes Hard drive failure. Possible USB failure. Corrective Action Ensure that the diskette drive and hard drive are properly connected. See Hard Drives for information on the drives installed in your system. See "Troubleshooting a USB Device" on page 156. No memory modules detected. See "Troubleshooting System Memory" on page 162. System board failure. See "Getting Help" on page 185. Memory configuration See "Troubleshooting System error. Memory" on page 162. Possible system board resource and/or system board hardware failure. See "Getting Help" on page 185. Possible system resource See "Getting Help" on page 185. configuration error. Other failure. Ensure that the diskette drive, optical drive, and hard drives are properly connected. See "Troubleshooting Your System" on page 155 for the appropriate drive installed in your system. If the problem persists, see "Getting Help" on page 185. About Your System 27

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204

About Your System
27
Hard drive failure.
Ensure that the diskette drive and
hard drive are properly connected.
See Hard Drives for information
on the drives installed in your
system.
Possible USB failure.
See "Troubleshooting a USB
Device" on page 156.
No memory modules
detected.
See "Troubleshooting System
Memory" on page 162.
System board failure.
See "Getting Help" on page 185.
Memory configuration
error.
See "Troubleshooting System
Memory" on page 162.
Possible system board
resource and/or system
board hardware failure.
See "Getting Help" on page 185.
Possible system resource
configuration error.
See "Getting Help" on page 185.
Other failure.
Ensure that the diskette drive,
optical drive, and hard drives are
properly connected. See
"Troubleshooting Your System" on
page 155 for the appropriate drive
installed in your system. If the
problem persists, see "Getting
Help" on page 185.
Table 1-1.
Diagnostic Indicator Code
(continued)
Code
Causes
Corrective Action