Dell PowerEdge T410 Hardware Owner's Manual - Page 33
Check PSU and, I/O channel - review
View all Dell PowerEdge T410 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 33 highlights
Table 1-2. LCD Status Messages (continued) Code Text Causes Corrective Actions E1620 Power Supply # (### W) AC power error. Check PSU cables. Specified power supply's AC input is outside of the allowable range. Check the AC power source for the specified power supply. If the problem persists, see "Troubleshooting Power Supplies" on page 161. E1624 Lost power supply redundancy. Check PSU cables. The power supply subsystem is no longer redundant. If the remaining power supply fails, the system will shut down. See "Troubleshooting Power Supplies" on page 161. E1626 Power Supply The power supplies in the Ensure that power Mismatch. PSU1 system are not the same supplies with matching = ### W, PSU2 wattage. wattage are installed. See = ### W. the Technical Specifications outlined in your system's Getting Started Guide. E1629 Power required > PSU wattage. Check PSU and config. The system configuration requires more power than the power supplies can provide, even with throttling. Turn off power to the system, reduce the hardware configuration or install higher-wattage power supplies, and then restart the system. E1710 I/O channel The system BIOS has check error. reported an I/O channel Review & clear check. SEL. Check the SEL for more information and then clear the SEL. Remove AC power to the system for 10 seconds and restart the system. If the problem persists, see "Getting Help" on page 185. About Your System 33