Table 1-2. LCD Status Messages (continued) Code Text Causes Corrective Actions E1420 CPU Bus parity The system BIOS has error. Power reported a processor bus cycle AC. parity error. Remove AC power to the system for 10 seconds and restart the system. If the problem persists, see "Getting Help" on page 185. E1422 CPU # machine check error. Power cycle AC. The system BIOS has Remove AC power to the reported a machine check system for 10 seconds and error. restart the system. If the problem persists, see "Getting Help" on page 185. E1610 Power Supply # Specified power supply See "Troubleshooting (### W) was removed or is missing Power Supplies" on missing. Check from the system. page 161. power supply. E1614 Power Supply # (### W) error. Check power supply. Specified power supply has failed. See "Troubleshooting Power Supplies" on page 161. E1618 Predictive failure on Power Supply # (### W). Check PSU. An over-temperature See "Troubleshooting condition or power supply Power Supplies" on communication error has page 161. caused the predictive warning of an impending power supply failure. E161C Power Supply # (### W) lost AC power. Check PSU cables. Specified power supply is attached to the system, but it has lost its AC input. Check the AC power source for the specified power supply. If the problem persists, see "Troubleshooting Power Supplies" on page 161. 32 About Your System