Dell PowerEdge T410 Hardware Owner's Manual - Page 81

Baseboard Management Controller Configuration, Entering the BMC Setup Module - server manual

Page 81 highlights

For more information about setting up USC, configuring hardware and firmware, and deploying the operating system, see the Dell Unified Server Configurator User's Guide on the Dell Support website at support.dell.com/manuals. Baseboard Management Controller Configuration NOTE: If an iDRAC6 Express card is installed on the system, the Baseboard Management Controller (BMC) utility is replaced by the iDRAC 6 utility. The BMC enables configuring, monitoring, and recovery of systems remotely. BMC provides the following features: • Uses the system's integrated NIC • Enables fault logging and SNMP alerting • Provides access to system event log and sensor status • Allows control of system functions including power on and off • Functions independently of the system's power state or the system's operating system • Provides text console redirection for system setup, text-based utilities, and operating system consoles NOTE: To remotely access the BMC through the integrated NIC, you must connect the network connection to integrated NIC1. For additional information on using BMC, see the documentation for the BMC and systems management applications. Entering the BMC Setup Module 1 Turn on or restart your system. 2 Press when prompted after POST. If your operating system begins to load before you press , allow the system to finish booting, and then restart your system and try again. Using the System Setup Program and UEFI Boot Manager 81

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204

Using the System Setup Program and UEFI Boot Manager
81
For more information about setting up USC, configuring hardware and
firmware, and deploying the operating system, see the
Dell
Unified Server
Configurator User’s Guide
on the Dell Support website at
support.dell.com/manuals
.
Baseboard Management Controller Configuration
NOTE:
If an iDRAC6 Express card is installed on the system, the Baseboard
Management Controller (BMC) utility is replaced by the iDRAC 6 utility.
The BMC enables configuring, monitoring, and recovery of systems remotely.
BMC provides the following features:
Uses the system’s integrated NIC
Enables fault logging and SNMP alerting
Provides access to system event log and sensor status
Allows control of system functions including power on and off
Functions independently of the system’s power state or the system’s
operating system
Provides text console redirection for system setup, text-based utilities, and
operating system consoles
NOTE:
To remotely access the BMC through the integrated NIC, you must connect
the network connection to integrated NIC1.
For additional information on using BMC, see the documentation for the
BMC and systems management applications.
Entering the BMC Setup Module
1
Turn on or restart your system.
2
Press <
Ctrl><E
> when prompted after POST.
If your operating system begins to load before you press <
Ctrl><E
>,
allow the system to finish booting, and then restart your system and try
again.