Dell PowerEdge T410 Hardware Owner's Manual - Page 34
Table 1-2., LCD Status Messages, Causes, Corrective Actions, Expansion Cards - reviews
View all Dell PowerEdge T410 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 34 highlights
Table 1-2. LCD Status Messages (continued) Code Text Causes Corrective Actions E1711 PCI parity error on Bus ## Device ## Function ## The system BIOS has Remove and reseat the reported a PCI parity error PCIe expansion cards. If on a component that the problem persists, see resides in PCI "Troubleshooting configuration space at bus Expansion Cards" on ##, device ##, function page 169. ##. PCI parity error on Slot #. Review & clear SEL. The system BIOS has Remove and reseat the reported a PCI parity error PCIe expansion cards. If on a component that the problem persists, see resides in the specified "Troubleshooting slot. Expansion Cards" on page 169. E1712 PCI system error on Bus ## Device ## Function ## The system BIOS has Remove and reseat the reported a PCI system PCIe expansion cards. If error on a component that the problem persists, see resides in PCI "Troubleshooting configuration space at bus Expansion Cards" on ##, device ##, function page 169. ##. E1714 Unknown error. The system BIOS has Check the SEL for more Review & clear determined there has been information and then SEL. an error in the system, but clear the SEL. Remove is unable to determine its AC power to the system origin. for 10 seconds and restart the system. If the problem persists, see "Getting Help" on page 185. E171F PCIe fatal error on Bus ## Device ## Function ## The system BIOS has Remove and reseat the reported a PCIe fatal error PCIe expansion cards. If on a component that the problem persists, see resides in PCI "Troubleshooting configuration space at bus Expansion Cards" on ##, device ##, function page 169. ##. 34 About Your System