Dell PowerEdge T410 Hardware Owner's Manual - Page 52
Sparing mode. See System, Troubleshooting a USB - memory slot configuration
View all Dell PowerEdge T410 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 52 highlights
Table 1-3. System Messages (continued) Message Causes Corrective Actions Sector not found Faulty hard drive, USB Seek error device, or USB medium. Seek operation failed Replace the USB medium or device. Ensure that the USB or SAS backplane cables are properly connected. See "Troubleshooting a USB Device" on page 156 or "Troubleshooting a Hard Drive" on page 167 for the appropriate drive(s) installed in your system. Shutdown failure General system error. See "Getting Help" on page 185. Sparing mode disabled. For sparing mode, matched sets of three must be populated across slots. The memory configuration Reconfigure the memory does not match the setting in modules for Memory BIOS. The BIOS setting has Sparing mode. See "System been disabled. Memory" on page 106. The amount of Memory has been added or system memory has removed or a memory changed module may be faulty. If memory has been added or removed, this message is informative and can be ignored. If memory has not been added or removed, check the SEL to determine if single-bit or multi-bit errors were detected and replace the faulty memory module. See "Troubleshooting System Memory" on page 162. 52 About Your System